background image

www.bullard.com

Safety Considerations and Limitations of Use

 

WARNING

EXPLOSION HAZARD.

 

DO NOT CONNECT OR DISCONNECT THE EQUIPMENT 

TO ANY CHARGER IN A HAZARDOUS LOCATION.

 

WARNING

DO NOT CHARGE IN A HAZARDOUS LOCATION.

 

WARNING

DO NOT SHORT CIRCUIT, CRUSH, INCINERATE, OR DISASSEMBLE. 

 

WARNING

RISK OF FIRE, EXPLOSION, OR BURNS. 

 

WARNING

ONLY CHARGE USING BULLARD DESKTOP, BULLARD TRUCK MOUNT, OR 

BULLARD PROVIDED USB PLUG.

POWER SOURCE: 3.6v 6400 mAh Li-Ion 23.04 wH

INTERNALLY HOUSED, NOT FIELD REPLACEABLE

 

WARNING

DO NOT ATTEMPT TO DISASSEMBLE THE BULLARD QXT THERMAL IMAGER. 

IF THE UNIT IS NOT FUNCTIONING PROPERLY, RETURN IT TO THE BULLARD 

SERVICE CENTER FOR EVALUATION. 

 

WARNING

DO NOT ATTEMPT TO REPLACE THE INTERNAL BATTERY PACK. RETURN IMAGER 

TO BULLARD SERVICE CENTER. BATTERY PACK MUST BE RECYCLED OR 

DISPOSED OF PROPERLY. 

 

WARNING

DO NOT USE ANY CHARGER OTHER THAN THAT SPECIFICALLY PROVIDED BY 

BULLARD FOR USE WITH THE BULLARD QXT THERMAL IMAGER. 

 

WARNING

THERMAL IMAGING IS NOT A TECHNOLOGY DESIGNED TO REPLACE CURRENT 

FIREFIGHTING TACTICS. RATHER, IT IS A TOOL WHICH ALLOWS THE 

FIREFIGHTER TO BE MORE EFFECTIVE AND TO MAKE BETTER DECISIONS. 

FIREFIGHTERS CANNOT STOP USING BASIC FIREFIGHTING SAFETY TACTICS. 

ALL FIREFIGHTERS SHOULD RECEIVE PROPER TRAINING ON: HOW THERMAL 

IMAGERS WORK, THEIR USES AND LIMITATIONS, IMAGE INTERPRETATION, 

AND SAFETY CONSIDERATIONS FOR THERMAL IMAGING USE.

 

WARNING

THE BULLARD QXT THERMAL IMAGER IS EXTREMELY SENSITIVE TO INTENSE, 

RADIANT HEAT SOURCES. NEVER POINT THE BULLARD QXT THERMAL IMAGER 

AT THE SUN OR ANY OTHER SOURCE OF EXTREME RADIANT HEAT, AS THIS 

COULD CAUSE SEVERE DAMAGE.

 

WARNING

DO NOT USE SOLVENTS OR PAINT THINNERS TO CLEAN THE BULLARD QXT 

THERMAL IMAGER AS THEY COULD PERMANENTLY MAR THE SURFACE 

OR DEGRADE THE PROTECTIVE PROPERTIES OF THE CASING. DO NOT 

INTENTIONALLY SUBMERGE THE UNIT UNDER WATER OR SUBJECT THE UNIT 

TO HIGH PRESSURE WATER. FOLLOW CARE INSTRUCTIONS  

(SEE CARE INSTRUCTIONS).

 

WARNING

BATTERY PACK CHARGING TEMPERATURE 0ºC - 45ºC

 

WARNING

ALWAYS USE THE CORRECT CHARGER AND REFER TO THE MANUFACTURER’S  

INSTRUCTIONS FOR PROPER CHARGING INSTRUCTIONS.  

RETAIN THE ORIGINAL PRODUCT LITERATURE FOR FUTURE REFERENCE.

 

6

Summary of Contents for QXT

Page 1: ...e Locating hot spots Identifying potential flashover situations Determining ventilation points Determining entry and exit points Overhaul Hazmat Wildland firefighting Incident investigation Training W...

Page 2: ...in high heat situations and deactivates as ambient heat decreases i e lower temperatures The low sensitivity mode indicator consists of a green triangle located in the upper left of the viewing area O...

Page 3: ...ction A second long press of both buttons will change from 2X to 4X zoom and a third long press of both buttons reverts to the Imager s standard view with no zoom SceneCatcher Digital Video Recorder D...

Page 4: ...rmation label the thermal imager lens cover window or the display Do not engrave in the plastic material as this can damage the unit and jeopardize sealing NOTE As an option the Bullard QXT may be ord...

Page 5: ...anty Bullard warrants to the original purchaser that the Bullard QXT and all features accessories installed in the unit as well as battery charging units are free of defects in materials and workmansh...

Page 6: ...OT ATECHNOLOGY DESIGNEDTO REPLACE CURRENT FIREFIGHTINGTACTICS RATHER IT IS ATOOLWHICH ALLOWSTHE FIREFIGHTERTO BE MORE EFFECTIVE ANDTO MAKE BETTER DECISIONS FIREFIGHTERS CANNOT STOP USING BASIC FIREFIG...

Page 7: ...Viewing Angle Typical Top 60 Bottom 40 Left Right 60 Standard Features Temperature Measurement Numeric and Bar Style Super Red Hot Colorization Engages automatically above 260 C Optional Features and...

Page 8: ...ee within USA 877 BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Europe Bullard GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Asia Pacific Bullard Asia...

Page 9: ...tnestern Hot Spots IdentifizierungpotenziellerFlash Over Situationen BestimmungvonVentilationspunkten ErmittlungvonEin undAusgangspunkten Brandwache Gefahrguteins tze Waldbrandbek mpfung Untersuchungd...

Page 10: ...wielautNFPA1801 Norm vorgeschrieben Akkustandanzeige 1 Viergr neSegmentewerdenangezeigt Kapazit tvon76 100 2 Dreigr neSegmentewerdenangezeigt Kapazit tvon51 75 3 ZweigelbeSegmentewerdenangezeigt Kapa...

Page 11: ...rTastenwirdwiederzur StandardanzeigederKameraohneZoomzur ckgekehrt Digitaler Videorekorder DVR SceneCatcher IhreBullardQXTistoptionalmiteinemVideospeicher DVR lieferbar ZurAktivierungdesVideospeichers...

Page 12: ...auf F r einebestm glicheLeistungempfiehltBullard dasGer tbeiNichtgebrauchdauerhaftin demLadesystemzulassen LegenSief rdieInstandhaltungderW rmebildkameraseinenWartungsplan fest HINWEIS Siek nnenIhreQX...

Page 13: ...ullard Garantie BullardgarantiertdemErsterwerber dassdieBullardQXTsowiealleeingebauten Komponenten Zubeh rteilesowieder AkkuundLadeger tebeientsprechendem EinsatzzweckundServicef reinenZeitraumvonf nf...

Page 14: ...LADEGER TE WARNHINWEIS DIEW RMEBILDTECHNOLOGIEWURDENICHTALSERSATZF RAKTUELLE FEUERWEHR EINSATZTAKTIKENENTWICKELT SIEISTVIELMEHREIN HILFSMITTEL DASSDENFEUERWEHRLEUTENERM GLICHT SCHNELLER EFFEKTIVEENTSC...

Page 15: ...keit 500cd m2 Kontrastverh ltnis 350 1 Sichtwinkel Oben 60 Unten 40 Links Rechts 60 Standard Funktionen Temperaturmessung NumerischundBalkenanzeige MehrstufigeEinf rbung ab260 C Optionale Funktionen E...

Page 16: ...BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Europe Bullard GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Asia Pacific Bullard Asia Pacific Pte Ltd L...

Reviews: