background image

1.  Enter a four digit personal 

identification number (PIN) of your 
choice on the keypad. Then press 
and hold ENTER.

2.  While holding the ENTER button, 

press and hold the LIGHT button 
on the Multi-Function Door 
Control.

3.  Continue holding the ENTER and  

LIGHT buttons while you press 
the push bar on the Multi-Function 
Door Control (all three buttons are 
held).

4.  Release buttons when the motor 

unit lights blink. It has learned the 
code. If light bulbs are not 
installed, two clicks will be heard.

To Add, Reprogram or Change a Keyless Entry PIN

NOTE:

 Your new Keyless Entry must be programmed to operate your garage door opener.

USING THE “LEARN” BUTTON 

USING THE MULTI-FUNCTION DOOR CONTROL

LOCK

LIGHT

LOCK

LIGHT

To change an existing, known PIN

If the existing PIN is known, it may be changed by one 
person without using a ladder.

1.  Press the four buttons for the present PIN, then 

press and hold the # button.

   The opener light will blink twice. Release the # 

button.

2.  Press the new 4-digit PIN you have chosen, then 

press ENTER.

The motor unit lights will blink once when the PIN has 
been learned.

Test by pressing the new PIN, then press ENTER. The 
door should move.

To set a temporary PIN

You may authorize access by visitors or service people 
with a temporary 4-digit PIN. After a programmed 
number of hours or number of accesses, this temporary 
PIN expires and will no longer open the door. It can be 
used to 

close

 the door even after it has expired. To set 

a temporary PIN:

1.     Press the four buttons for your personal entry PIN 

(not the last temporary PIN), then press and hold the 

 button.

   The opener light will blink three times. Release the 

button.

2.  Press the temporary 4-digit PIN you have chosen, 

then press ENTER.

  The opener light will blink four times.

3.  To set the number of 

hours

 this temporary PIN will 

work, press the number of hours (up to 255), then 
press 

.

OR

3.  To set the number of 

times

 this temporary PIN will 

work, press the number of times (up to 255), then 
press #.

The opener light will blink once when the temporary PIN 
has been learned.

Test by pressing the four buttons for the temporary PIN, 
then press ENTER. The door should move. If the 
temporary PIN was set to a certain number of openings, 
remember that the test has used up one opening. To 
clear the temporary password, repeat steps 1-3, setting 
the number of hours or times to 0 in step 3.

32

LOCK

L

I

GHT

One Button Close: 

Opener can be closed by pressing only the ENTER button if the one button close feature has 

been activated. This feature has been activated at the factory. To activate or deactivate this feature press and hold 
buttons 1 and 9 for 10 seconds. The keypad will blink twice when the one button close is active. The keypad will blink 
four times when one button close is deactivated.

NOTE: 

This method requires two people if the Keyless 

Entry is already mounted outside the garage. 

1.  Press and release the “learn” 

button on motor unit. The learn 
indicator light will glow steadily for 
30 seconds.

2.  Within 30 seconds, enter a four 

digit personal identification 
number (PIN) of your choice on 
the keypad. Then press and hold 
the ENTER button.

3.  Release the button when the 

motor unit lights blink. It has 
learned the code. If light bulbs are 
not installed, two clicks will be 
heard.

Summary of Contents for 3255BM 1/2 HP

Page 1: ...ease read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properl...

Page 2: ...opener 28 Having a problem 29 Diagnostic chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change a Keyless En...

Page 3: ...lement Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or...

Page 4: ...u proceed with the installation of your opener Access Door Safety Reversing Sensor Safety Reversing Sensor Slack in chain tension is normal when garage door is closed Gap between floor and bottom of d...

Page 5: ...Control Visor Clip Door Bracket Multi Function Door Control Panel L O C K L IG H T 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White Black Bell Wire attached Sa...

Page 6: ...nut on the trolley to obtain more chain slack Insert the second washered bolt CAUTION Use only the bolt previously removed from motor unit Tighten both bolts securely through the rail into the motor u...

Page 7: ...the risk of SEVERE INJURY or DEATH WARNING WARNING WARNING WARNING 1 READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS 2 Install garage door opener ONLY on properly balanced and lubricated ga...

Page 8: ...the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible...

Page 9: ...age Door Header Wall Garage Door UP CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEI...

Page 10: ...ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and join w...

Page 11: ...enient for setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way a...

Page 12: ...side of the motor unit to the structural support 2 Cut both pieces of the hanging bracket to required lengths 3 Drill 3 16 pilot holes in the structural supports 4 Attach one end of each bracket to a...

Page 13: ...ire in several places Do not pierce wire with a staple creating a short or open circuit 4 Strip 7 16 11 mm of insulation from end of bell wire Connect bell wire to the quick connect terminals as follo...

Page 14: ...le in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Secure...

Page 15: ...g cord Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be ground...

Page 16: ...15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the...

Page 17: ...p hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket again...

Page 18: ...lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction...

Page 19: ...epending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracke...

Page 20: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Page 21: ...re 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Brin...

Page 22: ...hers 5 16 Ring Fastener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully closed position Manua...

Page 23: ...rce as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still wo...

Page 24: ...ol clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount requ...

Page 25: ...bstruction and run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY...

Page 26: ...n the Light feature on the Multi Function Door Control is activated Bulb size is 100 watts maximum SAFETY SIGNAL light feature Lights will also turn on when someone walks through the open garage door...

Page 27: ...Wall Mounted Door Control THE MULTI FUNCTION DOOR CONTROL Press the push bar to open or close the door Press again to reverse the door during the closing cycle or to stop the door while it s opening...

Page 28: ...nually operate door If it is unbalanced or binding call a trained door systems technician Check to be sure door opens and closes fully Adjust limits and or force if necessary See pages 23 and 24 Repea...

Page 29: ...s to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adjust the...

Page 30: ...together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with jumper wire If...

Page 31: ...d 1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote that you wish...

Page 32: ...t the last temporary PIN then press and hold the button The opener light will blink three times Release the button 2 Press the temporary 4 digit PIN you have chosen then press ENTER The opener light w...

Page 33: ...oor control panel 2 371BM 1 Button remote control 3 10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope handle assembly 6 41B4494 1 2 Conductor bell wire w...

Page 34: ...s 8 30B532 Capacitor 1 2 HP 9 12A373 Capacitor bracket 10 41A3150 Terminal block w screws 11 41D3058 Universal replacement motor bracket assembly Complete with Motor worm bracket bearing assembly RPM...

Page 35: ...Enhanced functions include Lock Feature to lock out outside radio signals while you are away from home and turn opener lights on or off from the control panel 370LM 3 Button Mini Remote Control with...

Page 36: ...pair which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defect...