P2.x ATEX
1 Introduction
1.1 Intended Use
Sample gas pumps are intended for installation in gas analysis systems for industrial applications.
Atex versions are suitable for use in equipment group II, equipment category 2G, explosion group IIC, temperature classes T3 or
T3/T4 and must not be used in dusty areas.
P2.2 Atex / P2.4 Atex
II 2G Ex h IIC T3/T4 Gb X
P2.72 Atex / P2.74 Atex
II 2G Ex h IIC T3 Gb X
The sample gas pump is only intended to convey gaseous media. It is not suitable for liquids.
Please note the additional information in chapters "Product Description" and "Operation and Control" along with the informa-
tion on specific intended use, existing material combinations, as well as pressure and temperature limits in the data sheets.
When installed outdoors, ensure adequate protection from the weather, see chapter
Requirements to the installation site
[>
2
Bühler Technologies GmbH
BE420002 ◦ 07/2022