Bedienungs- und Installationsanleitung 

 

Installation- and Operation Instruction 

Nivotemp NT64 / Nivovent NV74          

 

 

 

BX100020 05/2014       Art. Nr. 9032037   

Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen, 

Tel. +49 (0) 21 02 / 49 89-0, Fax. +49 (0) 21 02 / 49 89-20 

Internet: www.buehler-technologies.com 

Email: 

[email protected]

 

 

 

 

 

 

 

 

 

 

 

Lesen Sie die Bedienungsanleitung vor dem Gebrauch des Gerätes gründlich durch. Beachten Sie 
insbesondere  die  Hinweise  unter  Gliederungspunkt  2.  Andernfalls  könnten  Gesundheits-  oder 
Sachschäden  auftreten.  Die  Bühler  Technologies  GmbH  haftet  nicht  bei  eigenmächtigen 
Änderungen des Gerätes oder für unsachgemäßen Gebrauch. 

 

Read  this  instruction  carefully  prior  to  installation  and/or  use.  Pay  attention  particularly  to  all 
advice  and  safety  instructions  to  prevent  injuries.  Bühler  Technologies  GmbH  can  not  be  held 
responsible for misusing the product or unreliable function due to unauthorised modifications. 

 

Summary of Contents for Nivotemp NT64

Page 1: ...dem Gebrauch des Ger tes gr ndlich durch Beachten Sie insbesondere die Hinweise unter Gliederungspunkt 2 Andernfalls k nnten Gesundheits oder Sachsch den auftreten Die B hler Technologies GmbH haftet...

Page 2: ...e 12 7 Anhang 23 7 1 Definitionen 23 7 2 Standard Anschlussbelegung f r NT64 und NV74 24 7 3 Technische Daten 25 7 4 Technische Daten Kontakte 26 7 5 Abmessungen 27 Contents Page 1 Introduction 13 1 1...

Page 3: ...Option zus tzlichen einen Bef lladapter Option BFA Die Niveauschalter der Serie Nivovent sind zus tzlich mit einem Bel ftungsfilter ausgestattet F r diese Typen stehen die folgenden Optionen zur Verf...

Page 4: ...Schaltpunkte lassen sich jederzeit auf die Bed rfnisse der Anlage einstellen Die Niveaukontakte befinden sich geschlossenen Geh usen Sie werden einfach auf einer Kontaktleiste mit vergoldeten Kontakte...

Page 5: ...ese Bedienungsanleitung ist Teil des Betriebsmittels Der Hersteller beh lt sich das Recht vor die Leistungs die Spezifikations oder die Auslegungsdaten ohne Vorank ndigung zu ndern Bewahren Sie die An...

Page 6: ...erden Unfallverh tungsvorschriften der Berufsgenossenschaften beachtet werden in Deutschland BGV A1 Grunds tze der Pr vention und BGV A3 Elektrische Anlagen und Betriebsmittel die zul ssigen Daten und...

Page 7: ...Sie im Anhang Die Niveaukontakte sind gem Bestellung als Schlie er ffner oder Wechsler ausgef hrt und in der angegebenen Lage montiert Sowohl die Lage als auch die Schaltfunktion k nnen ge ndert werde...

Page 8: ...zwerte eingesetzt werden Kontaktmaterial Bei allen Reedschaltern in B hler Niveaukontakten wird Rhodium als Kontaktmaterial im Bereich der eigentlichen Kontaktfl chen verwendet Rhodium hat im Vergleic...

Page 9: ...um 180 ge ndert werden Auf dem Geh use sind zwei Pfeile dargestellt Der Pfeil der nach oben zeigt weist auf die g ltige Kontaktfunktion hin HINWEIS Die Kunststoffschrauben nur mit maximal 5 cNm festz...

Page 10: ...Filterelement herausnehmen Die Befestigungsschrauben l sen und Filterbeh lter entfernen Die Schrauben des Flanschdeckels l sen und Deckel mit Deckeldichtung abnehmen Den Adapterstecker von der Kontak...

Page 11: ...enge l nachgef llt werden 4 1 Filterelement wechseln Zum Wechsel des Filterelements gehen Sie folgenderma en vor ffnen Sie den Filterdeckel durch Drehen gegen den Uhrzeigersinn Entnehmen Sie das Filte...

Page 12: ...St rungen und nach Einschalten der Netzspannung die korrekte Funktion nicht gegeben muss das Ger t durch den Hersteller berpr ft werden Bitte senden Sie das Ger t zu diesem Zweck in geeigneter Verpac...

Page 13: ...rial as the immersion tube MS VA With series Nivovent this option includes an additional filling adapter option BFA The Nivovent series is equipped with an air breather filter with the following optio...

Page 14: ...pes The switching points are changeable to the requirement of the individual application at any time The level contacts are placed in closed housings They are positioned on a gold plated printed circu...

Page 15: ...s GmbH unless described in this manual only original spare parts are used This manual is part of the equipment The manufacturer keeps the right to modify specifications without advanced notice Keep th...

Page 16: ...sponsible for the system must secure that safety and operation instructions are accessible and followed local accident prevention regulations and standards are obeyed performance data and installation...

Page 17: ...top Please find the pin assignment in the appendix The level contacts are designed as NO NC or change over contacts and are mounted in customized positions The position as well as the contact function...

Page 18: ...or SPS applications as well as for high loads within the maximum limits without hesitation Contact material All reed switches in B hler level contacts use rhodium as the contact material for the actua...

Page 19: ...rows The one pointing up when mounted indicates the current switching function NOTE The torque for the plastic screws must not exceed 5 cNm NO contact closed with rising level opens with falling level...

Page 20: ...he fixing screws and remove the filter housing Remove the flange cover and gasket Pull the adapter connector off and carefully pull out the punched strip Remove the plastic screws from the contact hou...

Page 21: ...g the Filter Element To replace the filter element proceed as follows Unscrew the filter cover counter clockwise Remove the filter element and dispose it according the National rules and standards Ins...

Page 22: ...of the type plate ready If the device doesn t work correctly after elimination of failures and turning power on the device must be checked by the manufacturer Please ship the device with suitable pac...

Page 23: ...n green K2 gelb yellow W2 schwarz black K3 rot red K4 blau blue NO Schlie er NC ffner TK Thermokontakt KT Temperaturtransmitter PT Temperatursensor Pt100 SSR Schwallschutzrohr Option NO normally open...

Page 24: ...se Connector 1 4 3 2 1 4 3 2 Nur Niveau kontakt e Typ K 3 PE 1 2 L1 L2 PE 4 5 L3 L4 3 6 1 2 L1 L2 2 3 1 4 L1 L2 level contacts only type K Nur Niveau kontakt e Typ W 2 3 PE 1 L1 PE 4 5 3 6 1 2 L1 L2 1...

Page 25: ...wimmer SK 601 PU PU float SK 601 Tauchrohr Messing brass Messing brass immersion tube Flansch PA PA flange Filtergeh use PA filter housing SSR Option Messing brass Messing brass SSR Option Ausf hrung...

Page 26: ...t load min Kontaktabstand 40 mm 1 57 in min contact distance Temperaturkontakt TK Temperature contact Schaltfunktion NO NC switching function max Spannung 30 V max voltage max Schaltstrom 2 5 A max sw...

Page 27: ...for VA with stilling tube 65 L1 min 40 44 L 280 370 500 3 5 4 L2 min 70 F000 59 3x 50 MS 60 3 VA min 60 BFA Bef lladapter filling adapter SSR Schwallschutzrohr mit Zentrierscheibe und Bef lladapter st...

Page 28: ......

Page 29: ...igt und dekontaminiert wurde und keinerlei Gefahren im Umgang mit dem Produkt bestehen I herewith declare that the device as specified above has been properly cleaned and decontaminated and that there...