High temperature
Burning hazard
Let the device cool down before starting maintenance or cleaning.
7.2.2 Replacing the Cooling Matrix
¾
Disconnect the motor from the mains supply and secure it against re-connection.
¾
Let the device cool down.
¾
Relieve the pressure and unscrew the hoses from the cooling matrix (use oil pan).
¾
Secure the cooling matrix against falling down. The element can be dismounted after unscrewing
the four screws between element and housing. The cooling matrices of size 6 to 8 provide M8
threads for lifting screws.
Do not lift the completely assembled cooler using these screws!
¾
Remount the new cooling matrix in reverse order. Check for the correct position of the oil terminals.
7.2.3 Replacing Fan Parts
¾
Disconnect the motor from the mains supply and secure it against re-connection.
¾
Let the device cool down and relieve system pressure.
¾
Remove the cords.
¾
Loosen the screws fixing the bracket to the coolers feet about two revolutions.
¾
Unscrew the four screws connecting the fan to the housing at the tips protective grating. The fan
can now be pulled out carefully to the back.
¾
When replacing the fan blade the screw has to be fixed with screw locking paste afterwards.
¾
Remount the new fan in reverse order.