Buffalo NBB3 Installation And Operating Instructions Manual Download Page 1

IS 619   ECN 3949

 

Page 1 of 10 

 

 

 
 

 

 
 
 
 
 
 
 

Installation, Operating and Servicing 
Instructions  

 
 
 
 
 
 
 

Electric Auto-Fill Water Boilers 
NBB3 AND NBB3F

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Please make a note of your product details for 
future use: 
 
Date Purchased:_________________________ 
 
Model Number:__________________________ 
 
Serial Number:__________________________ 
 
Dealer:_________________________________ 
 
_______________________________________ 

 

Summary of Contents for NBB3

Page 1: ...ill Water Boilers NBB3 AND NBB3F Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number ______________...

Page 2: ...tee 10 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that...

Page 3: ...nd clean the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DATA Model Height mm Width...

Page 4: ...odel Power kW Ambient temperature Deg C Water inlet pressure bar Water inlet pressure kPa NBB3 NBB3F 3 0 5 to 30 1 to 8 100 to 800 Electrical supply The units are supplied with a 13 amp plug Water sup...

Page 5: ...F G Fig 1 Only qualified or trained personnel should use this appliance First Use Switch on the water and electricity supplies Leave the boiler to fill for 30 minutes Drain off approximately 5 litres...

Page 6: ...rature will be displayed Press the power button to cycle through the values 70 96 Deg C Press the Fn button to select the required value The backlight adjustment screen is displayed next Press the pow...

Page 7: ...se a water jet or steam cleaner and do not immerse this appliance Clean all panels with warm water and mild detergent do not use abrasive materials Dry with a soft cloth Slide out and empty the drip t...

Page 8: ...d run the boiler normally for 30 minutes Isolate the boiler and allow the water to cool Remove both outer and tank lids again Inspect the tank and level sensor housings for scale deposits If necessary...

Page 9: ...AR Scale on level sensors Boiler overfilling Descale Check water inlet valve FILTER NO WATER FAULT SEE MANUAL STANDBY CLEAR Water turned off Inlet hose kinked or blocked Water pressure too high or low...

Page 10: ...not diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the manufacturer s instructions Consumable items such as filters glass...

Reviews: