▶ Replace the magnesium anode.
Visual check
▶ Shut off the cold water inlet.
▶ Depressurize the DHW cylinder (
▶ Remove and check the magnesium anode (
If the diameter is < 15 mm:
▶ Replace the magnesium anode (
▶ Check the transfer resistance between the earth connection and the
magnesium anode.
8
Environment/disposal
Environmental protection is a key commitment of the Bosch Group.
Quality of products, efficiency and environmental protection are equally
important objectives for us. Environmental protection laws and
regulations are strictly observed.
To protect the environment, we use the best possible technology and
materials while taking into account economic considerations.
Packaging
Where packaging is concerned, we participate in country-specific
recycling systems that ensure optimum recycling.
All of our packaging materials are environmentally compatible and can
be recycled.
Used appliances
Old appliances contain materials that must be recycled.
The relevant assemblies are easy to separate and all plastics are marked.
In this way the individual assemblies can be easily sorted and directed to
recycling or disposal.
9
Shutdown
▶ If an immersion heater has been installed (accessory), isolate the
DHW cylinder from the power supply.
▶ Switch off the temperature controller at the control unit.
▶ Drain the DHW cylinder (
▶ Shut down all the assemblies and accessories of the heating system
as specified in the manufacturer's technical documents.
▶ Close the shut-off valves (
Fig. 34, page 73 and Fig. 35, page 73).
▶ Depressurize the upper and lower indirect coils.
▶ Drain and blow out the upper and lower heat exchangers
(
To prevent corrosion:
▶ Leave the cover of the inspection port open, so that the interior can
dry out well.
Item
Description
1
Red cable
2
Screw for ground wire
3
Hand-hole cover
4
Magnesium anode
5
Thread
6
Ground wiring
7
Black cable
Table 10 Testing with the anode tester (
Never bring the surface of the magnesium anode into
contact with oil or grease.
▶ Keep everything clean.
WARNING: