Fitting the mounting bracket
SKR6.1R, SKR12.1R - Subject to technical modifications.
13
6
Fitting the mounting bracket
The collectors are connected to the structural element
using mounting brackets. The distances shown are using
the example of the mounting bracket for roof tiles.
B
Ensure there is safe access to the roof in compliance
with current legislation and health and safety
requirements.
Pre-assembly on the ground
In order to make installation on the roof easier for you, we
recommend that you pre-assemble the threaded
connections for all mounting brackets at ground level.
B
Secure the T-head bolt with washer and M10 nut onto
the mounting bracket.
Fig. 15 Pre-fitting the T-head bolts on the ground
6.1
Determining distances
B
In order to install the mounting brackets, you must
determine the distances for them. Please observe the
following guidelines (
Æ
Fig. 16):
– On tiled roofs, the position of tile valleys are used to
determine the true distance between the mounting
brackets.
– The rafter spacing does not always match the
required spacing for the mounting brackets. For
larger or smaller rafter spacing, you must install
suitable supports on site with adequate load-
bearing capacity (in doubt, consult a structural
engineer).
– For multiple rows of collectors, you must choose the
distances for the mounting brackets in such a way
that there is a minimum distance of 150 mm
between the collectors on the top and bottom.
– The mounting brackets must be positioned at right
angles to each other.
B
Define mounting bracket positions (
Æ
Fig. 16 to 20
NOTICE:
Damage to the roof by stepping on
installed mounting brackets and installation
set.
B
To prevent damage to the roof, do not
step on installed components.
6720646203-40.1ST
An example of the mounting bracket for roof
tiles is shown in the following tables. The
distances also apply to other mounting
brackets.
NOTICE:
Collector damage through
incorrectly positioned mounting brackets.
B
Maintain the distance between the
mounting brackets (
Æ
B
Always choose the largest possible
distance between two vertical mounting
brackets (
Æ
Fig. 16, Dimension b).
B
A rafter width of at least 88 mm is required
to fasten the mounting brackets with
3 screws. Provide for on-site
reinforcements in case of narrower rafters.