Positioning the boiler
6
Logano GB125 oil condensing boiler - Technical specifications are subject to change without prior notice.
25
B
Tilt the boiler with the aid of a trolley/truck (
B
Remove the angle strip.
B
Secure the plinth with M10 hexagon bolts supplied to
the boiler section feet at the front and rear.
B
Gently set the boiler down.
6.4
Positioning and levelling the boiler
You can level the boiler with the adjustable feet to pre-
vent air locks forming in the boiler block.
B
Move the boiler into its final location.
Level the boiler horizontally by turning the adjustable
feet using a spirit level.
Fig. 16
Fitting the boiler support to the front section
1
Boiler support on the front section
2
Boiler section feet of the front section
3
M10 hexagon screw
1
1
2
3
3
Fig. 17
Levelling the boiler horizontally