3.Operation instructions
3.1. Product panel description
BIT_V406R front panel
A: Industrial seat, RS232 control loop out, used in cascade
mode to loop out RS232 commands to the next device.
B:Network interface, TCP network protocol, is used for the
control system to issue instructions to control the device.
C:Industrial seat, used for RS232 control, used to issue RS232
commands.
D:Dip switch (Board id): indicates the ID of the current device
in cascade mode.V406 does not support this function, only
V409 supports it.
E:IR is used for receiving remote control signals,Need external
IR receiver.
F, G, H , I: 4 HDMI input ports, of which I port is 4K60,
F/G/H port is 4K30, suitable for graphics card output on PC