26
5.1
Technical data
5 Appendix
Power supply from BUS
18 – 27 Vdc
Absorption
75 mA (Stand-by with LEDs off)
85 mA (Stand-by with LEDs on)
105 mA (max in operation)
Load of local relay contacts
8 A, 30 Vdc
8 A, 30 Vac cosφ = 1
3,5 A, 30 Vac cosφ = 0,4
Operating temperature
(-25) – (+70) °C
Technical After-Sales Service
BTicino only accepts responsibility for perfect device operation if it is installed to the
state of the art respecting the indications of the product installation manual.