Summary of Contents for 353000

Page 1: ...User and installation manual www bticino com Sfera Keypad Module 353000 ...

Page 2: ...Sfera Keypad Module User and installation manual ...

Page 3: ...ra Speaker Module 351100 351200 351300 and Keypad Module 353000 12 Direct call with Sfera Speaker Module 351100 351200 351300 and Keypad Module 353000 13 Device configuration 14 Administrator code 14 New administrator code 14 Deleting administrator codes 17 Passepartout code 18 New passepartout code 18 Deleting administrator codes 21 Replacement of passepartout codes 22 Resident code 24 New reside...

Page 4: ...ation manual General information The Sfera Keypad Module must be used only on BTicino 2 wires digital systems Finishes that can be associated to the BTicino Sfera Keypad Module Front cover 353005 Front cover 353001 02 03 Front cover 353011 ...

Page 5: ...idden Installing the units near liquids and powders is forbidden Installing the units near heat sources is forbidden Installing the units near harmful gases metal dusts or similar is forbidden Fastening the units on unsuitable surfaces is forbidden Risk of devices falling because the surface on which they are installed collapses or inappropriate installation Switch the power supply OFF before any ...

Page 6: ...mination LED key for the selection of the door lock release code key for the replacement of the codes 2 Mini USB programming connector 3 Programming pushbutton 4 Red LED on steady access denied or programming error 5 Green LED on steady access granted or programming successful Front view ...

Page 7: ... Back view 1 Connection of door lock pushbutton CP P1 and tamper CP P2 future application 2 Local relay contacts 3 Connection to the BUS 4 Connector for the connection to subsequent modules 5 Connector for the connection to previous modules 6 Configurator sockets ...

Page 8: ...8 Sfera Keypad Module User and installation manual 1 2 3 Installation Caution Installation configuration starting up and maintenance must be performed exclusively by qualified personnel Mounting ...

Page 9: ...9 Sfera Keypad Module User and installation manual 4 5 6 ...

Page 10: ...10 Sfera Keypad Module User and installation manual 7 8 9 10 Disassembling 1 2 3 4 ...

Page 11: ...11 Sfera Keypad Module User and installation manual 5 5 7 8 6 ...

Page 12: ...s manual refers to the Sfera wired stand alone Keypad Module or paired with the Sfera Speaker Module 351100 351200 351300 If the Sfera Keypad Module is installed linked to the Display Module 352500 refer to the Display manual for the code programming Caution the secret code must consist of a minimum of 4 to a maximum of 9 digits Door lock control he TiSferaDesign software can be used to set the ma...

Page 13: ... module is configured with M 20 or M 23 Direct call with Sfera Speaker Module 351100 351200 351300 and Keypad Module 353000 Linking the Sfera Speaker Module and the Keypad Module allows direct call to an internal unit using the code Enter the call code 1 to 4 digits between 0 and 3999 The table below shows how to use the codes correctly ...

Page 14: ...r codes remove the front cover and press the programming button highlighted in the legend 1 2 Administrator code The ADMINISTRATOR code is required for safety reasons and is directly programmed by the installer The code grants access to the programming of the other codes passepartout and residents In order to access programming mode it will be necessary to assign an administrator code to the devic...

Page 15: ...lation manual 3 4 5 3 Enter the code 4 to 9 digits 4 Press the key A short beep confirms the programming of the new administrator code 5 Re enter the code to confirm Exact code Green LED ON and short beep Wrong code Red LED ON and long beep ...

Page 16: ...onds to exit the programming procedure A short beep and the switching off of the LED indicates that the programming sequence is complete The Sfera Keypad module is ready for normal operation During the programming procedure it will be necessary to follow some rules keys must be pressed in succession with maximum 2 seconds in between pressures the programming sequence must start within 30 seconds f...

Page 17: ...econd and a long beep after 10 seconds Deleting administrator codes The red LED flashes and then switches on to confirm that the deletion is complete The procedure will cancel all the saved administrator codes Press and hold down the programming button during the whole procedure To stop the deletion procedure release the programming pushbutton For selective deletion use the TiSferaDesign software ...

Page 18: ...inistrator code it is possible to program up to 20 passepartout codes The keypad module will indicate if the code is accepted or rejected through audible signals and the switching on of the green LED Entering an unrecognised code will cause the interruption of the programming procedure This interruption will be notified with an extended beep and the switching on of the red LED Note only with Sfera...

Page 19: ... User and installation manual 5 4 5 Re enter the code to confirm Exact code Green LED ON and short beep Wrong code Red LED ON and long beep 4 Press the key A short sound confirms the programming of the new passepartout code ...

Page 20: ...onds to exit the programming procedure A short beep and the switching off of the LED indicates that the programming sequence is complete The Sfera Keypad module is ready for normal operation During the programming procedure it will be necessary to follow some rules keys must be pressed in succession with maximum 2 seconds in between pressures the programming sequence must start within 30 seconds f...

Page 21: ... code three times in a row The device emits a long confirmation beep Deleting administrator codes The red LED flashes and then switches on to confirm that the deletion is complete The procedure will cancel all the saved Passepartout codes For selective deletion use the TiSferaDesign software ...

Page 22: ...2 Sfera Keypad Module User and installation manual 4 3 2 1 Replacement of passepartout codes 1 Press until the green LED starts flashing 2 Enter the passepartout code 3 Press the key 4 Enter the new code ...

Page 23: ...ely 1 second and then switches off During the programming procedure it will be necessary to follow some rules keys must be pressed in succession with maximum 2 seconds in between pressures the programming sequence must start within 30 seconds from the pressure of the programming button and must be completed in one stage 5 Press the key A short sound confirms the programming of the new passepartout...

Page 24: ... Resident code To access the programming of a RESIDENT code it will be necessary to have an administrator code It is possible to store up to 4000 codes one for each apartment The keypad module will indicate if the code is accepted or rejected through audible signals and the switching on of the green LED Entering an unrecognised code will cause the interruption of the programming procedure This int...

Page 25: ...odule User and installation manual 5 6 5 Press the A short beep confirms the programming of the new resident code 6 Re enter the code to confirm Exact code Green LED ON and short beep Wrong code Red LED ON and long beep ...

Page 26: ...gramming procedure A short beep and the switching off of the LED indicates that the programming sequence is complete The Sfera Keypad module is ready for normal operation During the programming procedure it will be necessary to follow some rules keys must be pressed in succession with maximum 2 seconds in between pressures the programming sequence must start within 30 seconds from the pressure of ...

Page 27: ...a confirmation beep and the green LED flashes The programming stage has started 3 Enter the administrator code again to confirm The device emits a long confirmation beep 2 Using the pushbutton module 352000 and 352100 select the apartment associated with the resident code to delete Note only with Sfera Speaker Module 351100 351200 351300 the associated Sfera Pushbutton Modules 352000 352100 ...

Page 28: ...28 Sfera Keypad Module User and installation manual The red LED flashes and then switches on to confirm that the deletion is complete ...

Page 29: ...29 Sfera Keypad Module User and installation manual 4 3 1 2 3 Press the key 4 Enter the new code Replacing resident codes 1 Press until the green LED starts flashing 2 Enter the resident code ...

Page 30: ... be necessary to follow some rules Keys must be pressed in succession with maximum 2 seconds in between pressures The programming sequence must start within 30 seconds from the pressure of the programming button and must be completed in one stage 6 Enter the code again to confirm The device emits a long confirmation beep 5 Press the key A short beep confirms the programming of the new resident cod...

Page 31: ... the Sfera Keypad Module After the reset the module will be set to the default settings 1 Keep the programming pushbutton pressed and reconnect the power supply keeping the button pressed until a beep is heard The red LED comes on steady for 4 seconds and then switches off In case of entrance panels with keypad module and speaker module after the reset wait at least 1 minute before restarting with...

Page 32: ...uration performed using the TiSferaDesign software or to update the firmware connect the Sfera Keypad Module to the PC using a USB miniUSB cable When updating the software the device must be powered The Sfera Keypad Module connected using a USB cable is recognised by the PC as a virtual port VIRTUAL COM Connection to the PC ...

Page 33: ...33 Sfera Keypad Module User and installation manual ...

Page 34: ...o Spa reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality the changes brought to the same BTicino SpA Viale Borri 231 21100 Varese www bticino com ...