Monobloc Audio
Digital Entrance Panel
Installer manual
7
2.3
Back view
1 - Microphone volume adjustment.
2 - Loudspeaker volume adjustment.
3 - Configurator socket:
P
= Entrance panel address (0 – 95)
N
= Address of the first called internal unit (0 – 99)
T
= Door lock control timer (see table*)
S
= Select the ringtone;
S = 0, 1, 2, 3
on the basis of the selection, the internal units ring with a different tone/tune
(Useful to differentiate several entrance panels on the same system);
S = 4, 5, 6, 7
on the basis of the selection, the internal units ring with a different tone/
tune (Useful to differentiate several entrance panels on the same system) and the recall
function (a series of 3 rings for each single call) is activated
4 - J2: remove to disable the sounds.
5 - J1: remove to enable the additional power supply.
6 - Connection to the BTicino 2 wire digital system BUS.
7 - Additional power supply connector.
8 - Door lock additional pushbutton connector.
9 - Door lock contacts connector.
P
N
T S
N T S
P P N
BUS
1 2 C NO NC PL
J1
J2
2
1
3
6
7
8
9
4
5
0
1
2
3
4
5
6
7
4 s 1 s 2 s 3 s 4 s 6 s 8 s 10 s
T
(
*)