5.2 - Maintenance Routines
34
SBT-2400 Service Instructions
M2041/5en
©BTG 2006
5.2 Maintenance Routines
5.2.1
Changing O-ring Seals
5.2.1.1
Wetted Part
1. Remove the old O-ring seal from the SBT-2400.
2. Mount the new O-ring seal. Use silicon grease to keep it in place during in-
stallation.
5.2.1.2
Housing
1. Remove the blade. See section 5.3.2.1:
Remove the Blade and Deflector
.
2. Remove the housing cover.
3. Remove the circuit board. See section 5.3.3.1:
Spare parts required:
O-ring seal
Consumable required:
(Silicon grease)
Spare parts required:
O-ring seal
Tools required:
Snap ring pliers
2.5 mm allen key/hexagon spanner
4 mm allen key/hexagon spanner
(Small pliers)
(Wise)
Consumable required:
(Silicone grease)