Page 2: ...BTEK_T419S_u_en_501787 book 2018 B TEK All rights reserved ...

Page 3: ...Powering up a T419S indicator 12 Using the alphanumeric keypad 12 Entering negative numbers or decimal point 12 Menu access and navigation 12 Escaping or exiting from a menu 13 Adjusting screen contrast 13 Chapter 3 Operating Instructions 14 Power Up 14 Accumulation weighing application 14 Gross weighing 14 Net weighing 15 Using the Accumulation function 17 Performing Accumulation weighments 19 Ch...

Page 4: ...4 T419S Indicator User Instructions ...

Page 5: ...unction it may be referred to by its alternate function Displayed messages appear in bold italic type and reflect the case of the displayed message Annunciator names appear as italic text and reflect the case of the annunciator 1 1 2 Special messages Examples of special messages you will see in this manual are defined below The signal words have specific meanings to alert you to additional informa...

Page 6: ...tion provided by the socket is suitable for the environment 1 3 Routine maintenance Always isolate the indicator from the power supply before starting any routine maintenance to avoid the possibility of electric shock CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to th...

Page 7: ...tory to the user Take frequent breaks during prolonged usage 1 6 Sharp objects Do not use sharp objects such as screwdrivers or long fingernails to operate the keys Table 1 1 Cleaning DOs and DON Ts DO DO NOT Wipe down the outside of standard products with a clean cloth moistened with water and a small amount of mild detergent Attempt to clean the inside of the machine Use harsh abrasives solvents...

Page 8: ...io communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le prés...

Page 9: ...ncludes two USB Host three serial ports and an Ethernet port Available options include l Analog Output kit l Current Loop kit Current loop and RS485 RS422 l USB Device kit Provides USB interface to PC l DeviceNetTM l ProfiBus l Wireless 802 11g l Internal 120 VAC relay l 2nd Scale Input 5VDC Excitation w o STVS l 2nd Scale Input 10 VDC Excitation w STVS l External I O Interface for existing GSE or...

Page 10: ...bove each one on the display The functions change according to program need Press the TARE key to perform a pushbutton tare function Acts as an up arrow key for menu navigation Press the SELECT key to toggle between the active display values Acts as a down arrow key for menu navigation Press the PRINT key to send information to a peripheral device through a configured communications port Acts as a...

Page 11: ...be used to perform custom application functions The ID key can be used to perform custom application functions The SCALE key can be used to perform custom application functions It can also be used to select the active scale when more than one scale is enabled The SETUP key can be used to perform custom application functions It can also be used to view the password entry screen for menu access The ...

Page 12: ...the current value from the display Then to enter a negative number with a single 0 displayed press the Decimal key The first character will then change to a negative sign Enter the rest of the digits normally To enter a decimal point or comma on a T419S use the decimal point key To enter a value less than 1 requires the entry of the leading 0 before a decimal point is allowed 2 5 Menu access and n...

Page 13: ...ping or exiting from a menu In any menu you will have either UP or ESC keys listed on screen If ESC is listed use it until it disappears then use the UP key until you are asked if you want to save any changes or not Highlight your choice and press ENTER to accept The indicator will reboot and return to the startup screen 2 6 Adjusting screen contrast To decrease or increase the screen contrast pre...

Page 14: ...cumulation app 3 2 1 Gross weighing To perform gross weighing power up the unit and follow these steps 1 Empty the scale and if necessary press ZERO to zero the display 0 is displayed and the center of zero annunciator lights 2 Place item to be weighed on the scale Weight is displayed 3 Repeat steps 1 and 2 SELECT key default function You can view the gross net tare gross total net total tare tota...

Page 15: ...eight on the scale if the display does not read 0 press ZERO 0 is displayed and the center of zero annunciator lights 2 Place item to be tared on the scale Weight is displayed 3 Press TARE 0 is displayed and the NET weight is displayed 4 Place material to be weighed into or on the tared item on the scale Net weight of material is displayed 5 Repeatedly press SELECT to view the gross tare and net v...

Page 16: ...the tare weight from the scale enter 0 then press TARE The tare is cleared and the scale is in gross weigh mode Using Preset Tare Preset tares are entered in a password protected menu Refer to details described in the Supervisor menu on page 26 There are 10 tare values stored in memory To perform a net weighment using one of the preset tares follow these steps 1 With no weight on the scale if the ...

Page 17: ...values PRINT key A brief key press or triggering input 3 accumulates and transmits data out serial port 1 See sample below Chan 1 Trans 2 Gross 52 lb Tare 25 lb Net 27 lb Press and hold the PRINT key to print the Total Format shown below if enabled in the supervisor menu Chan 1 Trans 2 Gross Total 1077 lb Tare Total 50 lb Net Total 1027 lb When the item is removed from the scale the Tare is cleare...

Page 18: ...the ENTER key The main screen appears with your chosen channel number displayed ID key F3 1 Press the ID key to enter an ID number The following screen appears Esc Clear 7 Characters Max Enter Channel 1 Remember to press the Num Lock key to enable the numeric keys kg Gross SETPT CHAN ID ID 0 0 Accum Chan 5 Net Total 0 lb Transactions 0 Esc Clear 7 Digits Max Enter ID 1 ...

Page 19: ...eight value for set point 3 4 Press ENTER to accept the displayed value or key in a new value and press ENTER to accept The indicator returns to the normal weighing mode 3 2 4 Performing Accumulation weighments The accumulator application can be used to record totals of individual weighments Follow these steps 1 Press ZERO to zero the scale if necessary 0 is displayed 2 Place empty container on th...

Page 20: ... steps 3 and 4 for each weight you want to accumulate If enabled press and hold the PRINT key to transmit current active total channel data out serial port 1 This will also clear the current active channel data if the clear feature is enabled under the Supervisor s Menu ...

Page 21: ... in 111 and press the ENTER key This screen is displayed The bold box around the center image means that is the highlighted menu item 3 Use the Left and Right keys to highlight the menu you want to enter and press the ENTER key Below are the explanations for these menus 4 1 User menu When the User menu is selected these choices appear Use the Left and Right keys to highlight the menu item you want...

Page 22: ...d to confirm a weighment if it is ever in dispute Only records that are qualified as a LEGAL record per site motion criteria are considered as entries to this log You can exit the menu by following the instructions in Escaping or exiting from a menu on page 13 4 2 About menu If you access the About menu you will see this menu The date format is how the date is stored internally Printed dates will ...

Page 23: ...w the network addresses IP Addr See the IP address Subnet See the Subnet address Gateway See the Gateway address MAC See the MAC address DLoad This stands for download Use this to view the following sSerial View the license number that created the configuration file dSerial View the license number that downloaded the configuration file dName View the company name for the license shown for download...

Page 24: ...through The audit report will contain both Config and Calib information Choices are Port 1 Under Port 1 choose to print to a column or ticket printer Port 2 Under Port 2 choose to print to a column or ticket printer USB Printing to USB requires that a USB flash drive is connected to the indicator host USB Printing to USB will create a folder on the flash drive and a comma separated file with the d...

Page 25: ...s Check connections and retry Print Aborted Something interfered with the printing process Check connections and retry Print Failed Something interfered with the printing process Check connections and retry 5 2 Copying to or from USB errors Failed to Copy File Something interfered with the copy process Check USB device Can t Close database Software error Restart indicator File Not Found File doesn...

Page 26: ...your desired port or to the USB port See Printed Preset Tare report example on page 27 rESEt Use this to clear all tares in memory AccuM Use this item to set the accumulation paramaters below Prt Tot This stands for Print Total If enabled during normal operation the user can press and hold PRINT for three seconds and the selected print format see Tot Fmt section below will be sent to any port that...

Page 27: ...Gross Total Net Total Tare TotalTransactions Units 1 111 1077 000000 1027 000000 50 000000 2 lb 2 0 0 000000 0 000000 0 000000 0 lb 3 0 0 000000 0 000000 0 000000 0 lb 4 0 0 000000 0 000000 0 000000 0 lb 5 0 0 000000 0 000000 0 000000 0 lb 6 0 0 000000 0 000000 0 000000 0 lb 7 0 0 000000 0 000000 0 000000 0 lb 8 0 0 000000 0 000000 0 000000 0 lb 9 0 0 000000 0 000000 0 000000 0 lb 10 1010 2966 000...