37
Technical information
Safety information
This equipment is approved to:
Low Voltage Directive, EN60950.
EMC Directive 89/336/EEC.
BABT, CTR-21.
Installation information
The Ultimate 106 connects to one exchange line and six (2 wire)
telephone extensions.
Signalling
DTMF.
Pulse dialling (typical 10 pps).
RECALL to external line – duration: 100ms.
type: timed break.
RECALL detection from extension – duration: 85ms to 200ms,
type: timed break.
REN
REN of the Ultimate 106 is 4.
Maximum REN per extension is 2.
Environmental conditions
Temperature range: (storage) –10
⬚
C to 60
⬚
C, (operating) 0
⬚
C to 55
⬚
C.
Humidity range: (storage) 65%, (operating) 60% maximum.
Ring cadences
Internal: 1s ON, 2s OFF.
External: 0.4s ON, 0.2s OFF, 0.4s ON, 2s OFF.
Door-phone: 0.5s ON, 2.5s OFF.
Alarm call: 0.5s ON, 0.3s OFF, 0.2s ON, 2s OFF.
Internal Ring-back: 0.2s ON, 0.2s OFF, 0.2s ON, 0.2s OFF, 0.2s ON, 2s OFF.
External Ring-back: 0.5s ON, 0.3s OFF, 0.2s ON, 2s OFF.
Power Supply (internal)
Power supply 220-240V AC 50/60Hz.
Power consumption 45W.
Weight
Weight 1.5kg.
Dimensions (approx.)
Height:
200mm.
Width:
295mm.
Depth:
48mm (52mm from wall).