11- 2
Service Guide
LWE180, LWE200, LPE200, LPE240
© BT Europe AB
Hydraulic/Pneumatik – 6000 LWE 180/200 LPE 200
Adjustments LWE180
T-code
Valid from serial number
Date
Order number
660, 661, 662, 497
723984-
2005-05-11
225553-040
11.3 Adjustments LWE180
11.3.1 Adjusting the pressure limit valve
The pressure limit valve is set to the correct value at the factory, but
may need to be adjusted if the valve or the complete hydraulic unit is
replaced.
The truck should be capable of lifting a load of between 1850-1900 kg.
1.
Locking nut. Use special tool, see drawing in chapter “Tools”.
2.
Adjuster screw, pressure limit.
Adjusting clockwise results in increased pressure.
Adjusting anticlockwise results in decreased pressure.
3.
Pressure limit valve. Use special tool, see drawing in chapter
“Tools”.
•
Loosen the locking nut (1) using a special tool (see drawing 3.2).
Place a load of 1800 kg on the forks and check that the truck can lift
it.
•
If the truck lifts 1800 kg, place a further 100 kg on the forks. Check
whether the truck can lift the load.
•
If the truck lifts 1900 kg, adjust the pressure limit by turning the ad-
juster screw (2) anticlockwise using a 4 mm allen key until the truck
cannot lift the load.
1
2
3