22
8. APPENDICES (continued)
8.3 Troubleshooting guide
Repairs and maintenance must be carried out by a qualified technician.
For more information, contact customer service.
Problem
Error
codes
Description
Solution
High pressure fault
E01
Pressure in the refrigerant circuit is
too high,
or water flow is too low,
or evaporator is blocked,
or air flow is too low.
Verify the high pressure switch and
the refrigerant circuit pressure.
Verify the water or air flow.
Verify that the flow switch is working
correctly.
Verify the water inlet/outlet valve
openings.
Check the bypass valve setting.
Low pressure fault
E02
Bypass open
Verify inlet T2 on the diagram.
Flow detector fault
E03
Water flow is insufficient or the
detector is in short-circuit or defective.
Check the water flow.
Verify the filtration pump and the
flow detector to see if they have any
possible problems.
Inflow/outflow temperature
difference > 13°C
E06
Insufficient volume of water flow
Verify the water flow or check if there
is a system obstruction.
Communication problem
E08
Problem with the LED controller or the
PCB connection.
Verify the connection of cables.
Water inlet sensor fault (IT)
P01
The sensor is open or short-circuiting
Verify or replace the sensor.
Water outlet sensor fault (AT)
P02
Outside temperature sensor
fault (OT)
P04
De-icing sensor fault (CT)
P05
Compressor backflow sensor
fault
P081
The sensor is open or presents a
short-circuit.
Verify or replace the sensor.
Operating limit reached
TP
Ambient temperature < 10°C
Shut off the heat pump.
Summary of Contents for Hayward Micro
Page 1: ...MANUALE di UTILIZZO Pompa di Calore HAYWARD MICRO www bsvillage com ...
Page 2: ......
Page 28: ...Page laissée blanche intentionnellement ...
Page 29: ...HEAT PUMP FOR ABOVE GROUND POOL Installation Instruction Manual MICRO ISMICRO_RevA ...
Page 54: ...Page intentionally left blank ...
Page 80: ...Página en blanco intencionalmente ...
Page 106: ...Página deixada em branco intencionalmente ...
Page 107: ...WÄRMEPUMPE FÜR FREISTEHENDES BECKEN Bedienungs und Installationsanleitung MICRO ISMICRO_RevA ...
Page 132: ...Seite bewusst leer gelassen ...
Page 133: ...WARMTEPOMP VOOR BOVENGRONDS ZWEMBAD Installatie en bedieningshandleiding MICRO ISMICRO_RevA ...
Page 158: ...Opzettelijk leeg gelaten pagina ...
Page 159: ...POMPA DI CALORE PER PISCINE FUORI TERRA Manuale d uso e di installazione MICRO ISMICRO_RevA ...
Page 184: ...Pagina lasciata intenzionalmente bianca ...
Page 185: ...VARMEPUMPE TIL SVØMMEBASSENG OVER BAKKEN Installerings og brukerveiledning MICRO ISMICRO_RevA ...
Page 210: ...Denne siden er blank med hensikt ...