register
regi_star_MA_Kap_3_en
Rev. 1.2.1 - 08/2014
13
• Adjust the traverse bar precisely. Take the above-mentionned requi-
rements into account.
• Screw / arret the assembly counter pieces to fix the traverse bar!
For further advice on mounting the terminal box and on the traverse bars
operation conditions, please see the provided documentation.
Repeat this procedure for all traverse bars.
3.2 Register Sensor Assembly
For a detailed register sensor assembly
see register sensor
manual chapter ASSEMBLY and COMMISSIONING.
3.3 Measuring Camera Assembly
For a detailed measuring camera assembly
see register measu-
ring cmaera manual chapter ASSEMBLY and COMMISSIONING.
3.4 Shaft Encoder Assembly
The shaft encoder is mounted on the print unit to synchronize the register
control with the web. There is a shaft encoder model which may only be
used in non-explosive areas and another one which may be used in zone 1.
Safety Instructions
WARNING!
Guarantee security at the shaft encoder assembly location
(if necessary, terminal boxes assembly location, too) before starting the
works. During the entire assembly works, the printing press must be fully
stopped and secured against restart. Possible consequences of non-
observance can be death or serious injury.
STOP!
Be careful when transporting and assembling the shaft encoder.
Protect the digitizer against impacts and don’t put weight on the encoder
shaft to avoid damages.
STOP!
Mount the shaft encoder only directly on the shaft. Do not mount
any machine elements like drives and gear belts between shaft encoder
and shaft to avoid damages on the shaft encoder.
For shaft encoder application in explosive areas:
The shaft encoder falls in machine category 2G and may only be used
in zone 1, zone 2 and in non-explosive areas.