Installation
4
CLS Pro 600 – Line and Contrast Sensor
35/108
4
Installation
4.1
Fitting the Cable Connections
WARNING
Caution!
All connecting cables must be laid without being tight and you
must ensure that there is no danger of anyone tripping over them.
1. Cable connections between the specific units (sensor, sensors,
actuator, etc.) must comply with the connection diagram.
2. Tighten up the securing screws in the plugs.
3. Ensure that the voltage supply has the correct potential equal-
isation in accordance with the local regulations.
4.2
Sensor
4.2.1
Enclosure Sockets
Fig. 33: Connections
Enclosure plug / socket
Function
Remark
x100
Control panel connection
(Plug)
x101
Controller Connection
(Socket)
x80
I/O Connection
(optional: Terminal Box BST eltro-
mat STB 1) connection box with
terminal strip for onsite connec-
tions;
see appendix 4
for layout
■
Analog O/P 0 - 10 V
■
External lighting , trigger O/P,
+12 V / 5 mA
■
External lighting, switched
a24 V
■
Error O/P, switched
a24 V