BT-64

MULTIFUNCTION IR THERMOMETER

OPERATION MANUAL

          1.     SAFETY RULES

To ensure that the meter is used safely, follow all safety and operating instructions in 

this operation manual. If the meter is not used as described in this operation manual, 

the safety features of this meter might be impaired.

Do not look directly into the laser beam when the device is in use–permanent eye 

damage may result.

Use extreme caution when operating the laser.

Never point the device towards anyone’s eyes.

Keep out of reach of children.

          2.     INTERNATIONAL SYMBOLS

          3.     SPECIFICATIONS

Important information

see manual

Laser device. Avoid towards 

anyone’s eyes

Item

Non-contact Infrared Scan 

Function

Thermocouple Probe Scan function

(K type; probe not included.)

-60 to +1000°C

(-76 to +1832°F)

-64 to +1400°C

(-83.2 to +2552°F)

Measurement 

Range

0 to +50°C (32 to 122°F)

±1% of reading or 1°C (1.8°F) 

whichever is greater (Test under 

Tamb.=23±6°C)

0.95 default – adjustable 0.1 to 1 step .01
0.1°C/0.1°F at -83.2 to +999.9(°C/°F), otherwise 1°C/1°F

1sec

1~99%, accuracy: ±3% from 20~80%, otherwise ±5%

Operating Range

Accuracy (Tamb= 

23±3°C)

±1.0°C (1.8°F)

Emissivity Range
Resolution

Relative Humidity

(Tamb=23±5degC

Response Time 

(90%)

30:1 (90% energy covered)

Distance: Spot
Internal Memory

Detailed 50 Memories with Temperature & Emissivity

-20 ~ +65°C, accuracy: ±2.5°C

          4.     THERMOMETER DESCRIPTIONS

5.     OPERATION

WARNING

The measurement range is for thermometers only. Users should choose proper probe 

types for different kinds of applications. Please make sure the target to be measured 

will not exceed the temperature range of the probe to avoid permanent damage to the 

thermocouple probe.
Caution: To avoid electric shock and thermometer damage, do not measure the live 

circuit with the thermocouple probe voltage exceeding 24V AC RMS or 60V DC.

EMC/RFI: Readings may be affected if the unit is operated within radiofrequency 

electromagnetic field strength of approximately 3 volts per meter, but the instrument's 

performance will not be permanently affected.

5.1     Function Selection
          Press Mode Key (4) for scrolling display functions as follows:

Display

Function
THB (thermal bridge detection) is the default mode.

Here will show the emissivity data. (The default emissivity is 

0.95.)

Press Mode key (4) for the 

Maximum (MAX), Minimum (MIN), 

Different between MAX and MIN (DIF) and Average (AVG) 

modes. During the measurement, the special modes reading 

will be displayed beside the mode icon

.

** The Thermometer will automatically shut off if left idle for more than 60sec., unless in PRB 

mode. (In PRB mode, it will shut off if left idle for more than 12 minutes.)

1)

2)

3)


Accuracy (Tobj=15-

35°C, Tamb=25°C)

Tobj=-60~0: ±(2+0.05/°C)°C,

Tobj=0~1000: ±2% of reading 

or 2°C (4°F) whichever is 

greater

Dry bulb 

temperature
Wet bulb 

temperature

-20 ~ +65°C, accuracy: ±2.5°C

Dew Point 

Temperature (DPT)

-50 ~ +50°C, accuracy: ±2.5°C from 20~30%RH; ±2°C from 

31~40%RH; ±1.5°C from 41~95 %RH

Battery Life

(Alkaline)

Typical 8 hours, minimum 7 hours continuous use (Alkaline battery, 

with laser and backlight)

Typical 32 hours, minimum 30 hours continuous use (Alkaline 

battery, with backlight but without laser)

Dimensions

53 x 124 x 171 mm (2.1 x 4.9 x 6.7 inch)

Weight

~240 g (8.5 oz) including batteries (AAA*2pcs)

(DPT) Display

(THB) Display

IRT (infrared temperature) – Tamb (temperature 

ambient) > 6.5°C:           icon displays “

red side 

flashing

”, the bar shows 

RED

 color, and “Hi” is 

beside the THB mode icon.

(a)

IRT - Tamb < -6.5°C:           icon displays “

blue 

side flashing

”, the bar shows 

BLUE

 color, and 

“Lo” is beside the THB mode icon.

(b)

IRT – Tamb > 5.75°C or < -5.75°C: The buzzer 

and optional vibration functions will start 

activating at the same time.

(c)

According to the following value, “CHK” (check) 

is displayed beside the THB mode icon and 

please continue to observe.

(d)

4.25°C < IRT - Tamb < 6.5°C: the bar shows 

RED

 color; -3.5°C 

 IRT - Tamb < 4.25°C: the bar shows 

YELLOW

 color; -6.5°C < 

IRT - Tamb < -3.5°C: the bar shows 

BLUE

 color.

Press Mode key (4), then press Up key (2) or Down key (3) to 

set the emissivity, then press Mode key (4) to confirm it. The 

emissivity can be changed from 0.10 (10E) to 1 (100E).

Press Up key (2) or Down key (3) to change the 

High Alarm 

(HAL)

 or 

Lo Alarm (LAL)

, then press Meas. key (6) to confirm it. 

When the reading is outside the 

High Alarm (HAL)

 or 

Lo Alarm 

(LAL)

 limit. The High or Low icon will flash and you will hear a 

beep sound.
Connect the thermocouple with Thermocouple Socket (10) and 

put the probe in/on the target, the thermometer will display the

temperature automatically without pressing any button. To see 

the minimum or maximum data during the probe measurement,

please hold down the Up key (2  or Down key (3).

After measure high temp, the probe may remain HOT for a 

while.

Press Mode key (4) for the 

RH% (relative 

humidity) mode

, then press Up key (2) for 

DBT 

(dry bulb temp)

WBT (wet bulb temp.) modes. 

During the measurement, the special modes 

reading will be displayed beside the mode 

icon.

(a) 60% < RH 

≦ 

75%: The screen displays          icon.

(b) 75% < RH 

≦ 

90%: The screen displays               icon.

(c) RH > 90%: The screen displays           icon.

After taking the temperature, press Mode key (4) for the 

Memory 

(M00)

, then press Meas. key (6) to save the measurement. 

Under the 

Memory (M00)

, press Up key (2) or Down key (3) key 

to display the record up to 50 sets. In “Memory” mode, press and 

hold the “Up” key, then press the “Down” key for 2 seconds to 

clear the records.

Press Mode key (4) for 

DPT (dew point 

temperature) modes. During the measurement, 

the special modes reading will be displayed 

beside the mode icon

.

(a) IRT (infrared temperature) - DPT (dew point temperature) 

> 1.9°C: The bar shows 

YELLOW

 color.

(b) 1.1°C < IRT - DPT 

≦ 

1.9°C: The bar shows 

Blue

 color and 

displays          icon.

(c) -0.5°C < IRT - DPT

1.1°C: The bar shows 

Blue

 color and 

displays              icon.

(d) IRT - DPT

-0.5°C: The bar shows 

Blue

 color and

displays           icon.

In (b), (c) and (d) cases, the icon     ,         ,        is the indication 

for the risk of condensation as well as mold warning, the buzzer 

and optional vibration functions are activated at the same time.

Class Illa Laser

Laser

Note: Not recommend using external K-type thermocouple for long time measurement

          above 1000°C (1832°F)