3 1/2 Digits Unbeatable Best Buy Multimeters with All-Ranges Protection 

OPERATION MANUAL 

1.  SAFETY RULES 

 

 

This meter is designed and tested in accordance with EN publication 61010-1, pollution 

degree II and installation category (overvoltage category) II 600V. 

 

This meter has been tested according to the following EC Directives 

 

89/336/EEC Electromagnetic Compatibility, EN61326

 

 

73/23/EEC Product safety law of Low Voltage Directive, EN61010-1 

 

This meter is designed to be indoor use at temperature 5

°

C to 40

°

C and altitude up to 

2,000m. 

 

To ensure that the meter is used safely, follow all safety and operating instructions in 

this operation manual.    If the meter is not used as described in this operation manual, 

the safety features of this meter might be impaired. 

 

2.  INTERNATIONAL SYMBOLS 

 

Important information 

 

Diode 

 

see manual 

 

Continuity 

 

AC 

 

Ground 

 

DC 

 

Double insulation 

 

3.  SPECIFICATIONS 

3.1 General Specifications 

Display 

:  3 1/2 digit LCD with max. reading of 1999. 

Polarity 

:  Automatic, (-) negative polarity indication. 

Zero adjustment 

:  Automatic. 

Over range indication 

:  Only the MSD “1” is displayed. 

Power 

:  1.5V AAA battery x 3 

Dimension 

:  85 (W) x 155 (H) x 40 (D) mm. 

Net Weight 

:  Approx. 250g. (Including battery). 

 

3.2 Electrical Specifications 

Accuracies are 

±

 (% of r number of least significant digits) at 23

°

±

 5

°

C, <75% RH. 

DC Voltage 

Range 

Resolution 

Accuracy 

Input 

Impedance 

Overload 

Protection 

200mV 

0.1mV 

±

(1.0%+3) 

10M

 

 

600V DC/ACrms   

 

2V 

1mV 

20V 

0.01V 

200V 

0.1V 

600V 

1V 

AC Voltage 

Range 

Resolution 

Accuracy 

Frequency 

(Hz) 

Overload 

Protection 

200V 

0.1V 

±

(1.2%+3d) 

40~400 

600V DC/ACrms 

600V 

1V 

DC Current 

Range 

Resolution 

Accuracy 

Overload 

Protection 

20mA 

0.01mA 

±

(1.2%+3d) 

250V DC/ACrms 

200mA 

0.1mA 

10A* 

0.1A 

±

(5.0%+3d) 

Resistance 

Range 

Resolution 

Accuracy 

Open circuit 

voltage 

Overload 

Protection 

200

 

0.1

 

±

(1.2%+3d) 

<1.0V 

250V DC/AC rms 

<30 sec. 

2k

 

0.001k

 

20k

 

0.01k

 

200k

 

0.1k

 

2M

 

0.001M

 

Capacitance 

(BS1902/03)   

Range 

Resolution 

Accuracy 

Test 

Volt/Freq 

Overload Protection 

20

µ

0.01

µ

±

(2.5% + 3d)  <3V/2.5Hz 

250V DC/AC rms 

<30 sec 

200

µ

0.1

µ

Temperature 

(BS1903)

 

Range 

Resolution 

Accuracy 

Overload Protection 

-20

°

C to 

+400

°

1

°

±

(2.5% + 4

°

C) 

250V DC/AC rms <30 sec. 

Diode Test 

 

 

Test Voltage 

Test Current 

Overload Protection 

<3V 

Approx. 1.6mA 

250V DC/AC rms 

<30 sec. 

Continuity 

Test 

 

 

Test range 

Open circuit 

Voltage 

Overload 

protection 

Buzzer sounds when 

resistance value 

<30

 

<3V 

250V DC/AC rms 

<30 sec. 

Transistor Test 

(NPN-PNP) 

(BS1901/02/03)

 

range 

hFE Value 

Overload 

protection 

hFE 

0 – 1000 

250V DC/AC rms 

<30 sec. 

Phase Sequence 

Indication   

Range 

Phase Sequence Indication 

380ACV 

±

10% 

Correct Phase Sequence 

– Phase Sequence Light “ON” 

Live Wire 

Verification Voltage 

Tested Voltage Range 

100~250V 

Battery Test 

(BS 1901) 

Range 

Load Resistance 

Overload Protection 

1.5V load 

150

 

250V DC/AC rms 

<30 sec. 

12V load 

900

 

Square 

Waveform Output 

(BS 1901W)

 

Output Voltage  Frequency  Wave Form 

Overload Protection 

Approx. 3V 

50Hz 

Square 

Wave 

250V DC/AC rms 

<30 sec. 

* for BS1903 only, use 10A fused current adaptor at 200mV range 

 

 

 

 

 

4.  PANEL DESCRIPTIONS 

 

 

1. 

Live wire verification indication light 

(BS1901/01W) 

2. 

LCD display 

3. 

Transistor testing socket 

(BS1901/02/03); Battery test key 

(BS1901W) 

4. 

Multifunction selector 

5. 

HOLD key / Battery test key 

6. 

Phase verification indication light 

7. 

Input terminal 

 

 

5.  OPERATION 
 

!

WARNING 

1)  When measuring voltage ensure that the instrument is not connected or switched to a 

current or resistance, or battery test, or diode/ continuity check range. Always ensure that 

the correct terminals are used for the type of measurement to be made. 

2)  Use extreme care when measuring voltage above 50V, especially from sources where 

high energy exists. 

3)  Avoid making connections to “live” circuits whenever possible. 

4)  When performing current measurements ensure that the circuit is not “live” before opening 

it in order to connect the test leads. 

5)  Before performing resistance/capacitance  measurements or diode test, ensure that the 

circuit under test is de-energised. 

6)  Always ensure that the correct function and range is selected. If in doubt about the correct 

range, start with the highest and work downwards. 

7)  Extreme care should be taken when using the instrument to conjunction with a current 

transformer connected to the terminals. High voltage may be produced at the terminals if 

an open circuit occurs. 

8)  Ensure that the test leads and prods are in good condition with no damage to the 

insulation. 

9)  Take care not to exceed the overload limits as given in the specifications. 

 

5.1  DC and AC voltage measurement 

1.  Connect the black test lead to the “COM” terminal and red test lead to the “V” terminal. 

2.  Set the multifunction selector to desired DC V or AC V position and connect the test leads 

across the source or load under measurement. 

 

5.2  DC current measurement 

1.  Connect the black test lead to the “COM” terminal and red test lead to the “mA” terminal 

for measurement up to 200mA. 

2.  Set the multifunction selector to desired current range position. 

3.  Connect the test leads in series with the current source to be measured. 

4.  When the tested current is above 100mA, the input voltage drop might above 1V; hence, 

the test duration cannot exceed 15 seconds!   

!

CAUTION: Max. input overload: 250V rms < 20sec. 

 

5.3  Resistance measurement 

1. 

Connect the black test lead to the “COM” terminal and red test lead to the “Ω” terminal.

 

2.  Set the multifunction selector to desired resistance 

(Ω) range position.

 

3.  Connect the test leads across the circuit to be tested. 

!

CAUTION:    Ensure that the circuit to be tested is “dead”. 

           

Max. input overload : 250V rms < 20sec. 

 

5.4  Capacitance Measurement 

(BS1902/03)

 

1.  Connect the black test lead to the “COM” terminal and red test lead to the “

” terminal. 

2.  Set the multifunction selector to desired Capacitance (C) range position. 

3.  Connect the test leads across the capacitance to be tested. 

!

CAUTION:    Ensure that the capacitance to be tested is discharged. 

           

Max. input overload : 250V rms < 20sec. 

 

5.5  Temperature  Measurement (with K-Type 

Thermocouple) 

(BS1903)

 

1.  Connect the K-Type Thermocouple cathode (-) to 

the “COM” terminal and the anode (+) to “

°

C” 

terminal. 

2.  Set the multifunction selector to “

°

C” range 

position. 

3.  Use the K-Type Thermocouple’ probe contact the 

object to be tested (Liquid) 

4.  If the temperature of the environment is sudden 

changed or the resettable fuse is in active mode, 

the  temperature  measurement should continue 

after 30 minutes; otherwise, the measurement is 

not accurate. 

 

 

5.6  Diode test 

1.  Connect the black test lead to the “COM” terminal and red test lead to the “

” terminal. 

2.  Set the multifunction selector to 

  (same as    ) position. 

3.  Connect the black and red test leads to the cathode (-) and anode (+) ends of the diode 

to be tested respectively. 

4.  Read the forward voltage drop (junction) value from the display. When the forward biased 

is open, the display will shows overload ‘1’ . 

!

CAUTION: Max. input overload: 250V rms < 20sec. 

 

5.7

 

Transistor (NPN/PNP) Test

 (BS1901/02/03)

 

1.    Set the multifunction selector to hFE position, the meter will display 000 

2.  Connect the transistor’s pin to the testing socket according to the type of the transistor, 

the meter will display transistor’s  hFE value, if display abnormal value, it mean wrong 

connection is made or the transistor is damage. 

!

CAUTION: Max. input overload: 250V rms < 20sec. 

!