Fault diagnosis
2016-03-10 / DIS 184_58300000140186_ara_en_k
Copyright by BSH Hausgeräte GmbH
Page 58 of 181
4.5
Leaks
Fault
Possible cause
Troubleshooting
Steam escapes in the top right-hand
corner
(Condensed water on the control mod-
ule)
Vapour valve incorrectly assembled.
The retaining tabs of the vapour valve are
not latched into the air baffle.
-
Incorrect assembly has left a gap that allows „external air" to be drawn in.
-
The steam is therefore not properly extracted via the ventilation duct.
► Assemble the vapour valve correctly.