
Test
2017-03-23 / DIS 184_58300000197442_ARA_EN_A
Copyright by BSH Hausgeräte GmbH
Page 42 of 101
5.1
Measure the distance between the front glass
panel and the cabinet cavity
Required tools:
?
Callipers [ 00341574]
Prerequisite:
The appliance must be flush to the cabinet cavity at left, right, top and bottom.
If an eFSB is being compiled, four photos showing calliper
readings must be attached.
All measurements must be documented in a measurement
protocol.
► Measure the distance at all four positions.
Result:
Target distance = 19 mm ± 1 mm