Fault diagnosis
2017-03-23 / DIS 184_58300000197442_ARA_EN_A
Copyright by BSH Hausgeräte GmbH
Page 41 of 101
Fault
Possible cause
Troubleshooting
The vapour valve and/or the air baffle are
distorted because of faulty TOX points.
-
A production fault at the TOX points has the effect of allowing the vapour valve to
distort when it is screwed tight.
-
This leaves a gap that allows “external air” to be drawn in.
-
This prevents the steam from being properly extracted via the ventilation duct.
-
There may not be
any
gap between the vapour valve and the air baffle.
► Check whether the air baffle was distorted due to faulty TOX points on the vapour
valve.
► Replace the distorted air baffle.
► Replace the distorted vapour valve.
Water drips onto the floor or furniture
when the door is opened
Not a fault. Current state of technology.
During condensation-intensive operation,
condensation collects in the door seal and
then accumulates up the door panel.
-
Fault only occurs on appliances without steaming function.
-
The condensation strip can
not
be installed on appliances with a microwave.
?
Condensation strip [ 11003837]
?
Panel holder [ 11003838]
?
Self-tapping screws 00611413
► Retrofit condensation strip.
Vapour/condensation escapes
Vapour valve does not close correctly.
►