background image

1

Bedienungsanleitung

Instruction Manual

33er E-Serie 

33 E-Series

Summary of Contents for 33 E Series

Page 1: ...1 Bedienungsanleitung Instruction Manual 33er E Serie 33 E Series...

Page 2: ...hnische Daten 4 Montageanleitung Estrichboden 5 Montageanleitung Hohlboden 9 Gebrauchshinweise 21 Product description 3 Technical data 4 Assembly instructions screed floor 13 Assembly instructions rai...

Page 3: ...eprinzip gilt f r alle Bodensteckdosen der 33er E Serie 3301E 3302E 3303E The 3302E floor socket is shown as an example The installation principle applies to all floor sockets from the 33E Series 3301...

Page 4: ...en 2x unten je 25mm Nivellierbar Schutzart IP20 IP20 IP20 Belastbarkeit Fl chenlast max 120kg Fl chenlast max 120kg Fl chenlast max 120kg Item No 3301E 3302E 3303E Instl dim 102x 88x60mm 146x90x60mm 2...

Page 5: ...L Schritt 2 Vor dem Gie en des Estrichs einen Polystyrol Block PB der in seiner u eren Abmessung umlaufend ca 40mm gr er ist als die Dose als Platzhalter auf die ausgelegte D mmschicht P kleben Danac...

Page 6: ...ng auf ein M rtelbett M einsetzen und die Leerrohre L in die ffnungen der Box einf hren 4 t E W Achtung Die H he des M rtelbetts muss so vermessen werden dass der Abstand t zwischen Wasserwaage W und...

Page 7: ...ox abdichten Tipp die Box beispielsweise mit Pappe D abdecken wie abgebildet Die Aussparung um die Box nun mit M rtel M auff llen Die Position der Box vor dem Aush rten des M rtels mit der Wasserwaage...

Page 8: ...den Belag B im Raum verlegen Danach den Rahmen mit dem Deckel wieder in die Box einschrauben Zuletzt die Steckdosen anschlie en und den Ger tetr ger einschrauben Die Bodensteckdose ist nun erfolgreich...

Page 9: ...9 Montage im Hohlboden Schritt 1 Den Ger tetr ger und den Deckel vom Rahmen abschrauben...

Page 10: ...10 L H Schritt 2 An gew nschter Position einen Ausschnitt in der Gr e der Box Einbauma e in den Hohlboden H s gen schneiden Die Leehrohre Leitungen L zu dieser Position verlegen...

Page 11: ...ngen L von unten oder seitlich in die Box einf hren Anschlie end Konstruktionskleber K z B beko ALLCON 10 rund um den Ausschnitt auf dem Hohlboden H verteilen Nun die Bodensteckdose in den Ausschnitt...

Page 12: ...12 Schritt 4 Die Steckdosen anschlie en danach den Ger tetr ger und den Deckel anschrauben Fertig...

Page 13: ...Step 2 Before pouring the screed a polystyrene block PB with a circumference of approx 40 mm larger than the box in its outer dimension must be glued to the insulation layer P as a placeholder Then l...

Page 14: ...ed E is as large as the subsequent covering thick ness In addition the mortar bed must be designed for the corresponding load on the floor socket Step 3 Remove the polystyrene block PB after pouring t...

Page 15: ...M Step 4 Seal the box Tip cover the box for example with cardboard D as shown Now fill the recess around the box with mortar M Check the position of the box with the spirit level W before curing the m...

Page 16: ...reed E has hardened lay the covering B in the room Then screw the frame with the lid back into the box Finally connect the sockets and screw in the device carrier The floor socket is now successfully...

Page 17: ...17 Installation in the raised access floor Step 1 Unscrew the device carrier and the lid from the frame...

Page 18: ...18 L H Step 2 Saw cut a cut out in the size of the box installation dimensions into the raised floor H at the desired position Then lay the conduits L to this position...

Page 19: ...the conduits L into the box from below or from the side Then spread the cons truction adhesive K e g beko ALLCON 10 around the cutout on the raised floor H Now put the floor socket into the cutout and...

Page 20: ...20 Step 4 Connect the devices and screw the device carrier and the lid back into the frame Ready...

Page 21: ...nicht in Betrieb genommen werden Das Produkt ist unter Beachtung der nationalen Vorschriften zu entsorgen Irrt mer und technische nderungen vorbehalten In order to ensure a lasting function of the flo...

Page 22: ...n Subject to errors and technical changes by BS Bodensteckdosen Systemtechnik GmbH BS Bodensteckdosen Systemtechnik GmbH Dingerdisser Str 36 33699 Bielefeld Tel 49 5219892780 Fax 49 521989278 30 info...