background image

Fig. 12—Single-Speed Air Conditioner

with Variable Speed (FK4D, FV, 40FK) Fan Coil

R

Y/Y2

R

Y

W/W1

W1

C

MODEL AC 01-C

THERMOSTAT

EASY SELECT

TERMINAL BOARD

SINGLE-SPEED

AIR CONDITIONER

J1 JUMPER

J2 JUMPER

See note 10 and 11

W2

Y/Y2

DH

G

G

Y1

O

C

HEAT STAGE 1

24 VAC HOT

C

COOL STAGE 1

FAN

24 VAC COMM

A98463

Fig. 10—Two-Speed Air Conditioner

with Typical Fan Coil

24 VAC HOT

24 VAC COMM

HEAT STAGE 1

COOL STAGE 2

FAN

R

C

G

W/W1

Y/Y2

R

C

HEAT STAGE 2

COOL STAGE 1

N/A

OUTDOOR

SENSOR

CONNECTION

Y1

B

S1

S2

C

Y1

MODEL 2S 01-c

THERMOSTAT

TYPICAL

FAN COIL

TWO-SPEED

AIR CONDITIONER

See notes 2, 4, 5, 6, 

8, 

10 and 11

Y

G

O/W2/B

*

W2

R

Y2

E

W3

A98459

Fig. 13—Single-Speed Air Conditioner

with Variable-Speed (FK4D, FV, 40FK) Fan Coil

A98464

24 VAC HOT

HEAT STAGE 1

24 VAC COMM

COOL STAGE 1

FAN

R

G

W/W1

Y/Y2

R

Y

C

C

C

MODEL HP 01-C

THERMOSTAT

EASY SELECT

TERMINAL BOARD

SINGLE-SPEED

AIR CONDITIONER

J1 JUMPER

REMOVE

J2 JUMPER

FOR HEAT

STAGING

See notes 2, 4, 10 and 11

G

W1

Y/Y2

DH

HEAT STAGE 2

N/A

N/A

OUTDOOR

SENSOR

CONNECTION

Y1

B

S1

S2

O/W2/B

Y1

O

W2

Fig. 11—Two-Speed Heat Pump

with Typical Fan Coil

A04011

24 VAC HOT

24 VAC COMM

COOL/HEAT

STAGE 2

R

C

G

W/W1

Y/Y2

R

C

RVS COOLING

COOL/HEAT

STAGE 1

N/A

OUTDOOR

SENSOR

CONNECTION

Y1

B

S1

S2

W3

C

Y1

MODEL 2S 01-C

THERMOSTAT

TYPICAL

FAN COIL

TWO-SPEED

HEAT PUMP

See notes  5, 6, 7, 

8, 

10

,

 and 11

Y

G

*

W2

R

Y2

E

O

W1

HEAT STAGE 3

FAN

O/B/W2

—8—

Summary of Contents for TSTATBBN2S01-C

Page 1: ...lication Models are AC 1 stage cool 1 stage heat for AC systems only HP 1 stage cool 2 stage heat for either HP or AC with 2 stage heat 2S 2 stage cool 2 stage heat for 2 speed AC systems or 2 stage c...

Page 2: ...on page 11 for explanation IV SET THERMOSTAT CONFIGURATION Configuration options are intended to be selected at installation and are normally not modified by the home owner These options are not disc...

Page 3: ...D Option 04 G Fan On With W W1 Output This selection determines whether the G fan output is to be ON or OFF when any W furnace or strip heat output is ON Most furnaces and fan coils manage their own b...

Page 4: ...ween 5 and 5 Factory default is 0 This adjusted value will be used as actual temperature for both display and control action For example if 2 is selected 72 F actual will read 74 F If setpoint is 72 t...

Page 5: ...ler test will be initiated by pressing the fan button for 20 seconds 15 seconds will enter installer setup InS will appear on the screen and the SERVICE icon will be illuminated In installer test mode...

Page 6: ...R CONDITIONER See notes 6 10 and 11 Y G W2 E W3 HEAT STAGE 1 FAN A98453 Fig 2 Single Speed Air Conditioner with Single Stage Furnace A04006 24 VAC HOT 24 VAC COMM HEAT STAGE 1 COOL STAGE 1 FAN R C G W...

Page 7: ...ED AIR CONDITIONER See notes 2 4 6 10 and 11 Y G O W2 B W2 E W3 A98455 Fig 9 Two Speed Air Conditioner with 2 Stage or Variable Speed Furnace A04010 24 VAC HOT 24 VAC COMM HEAT STAGE 1 COOL STAGE 2 FA...

Page 8: ...2 4 5 6 8 10 and 11 Y G O W2 B W2 R Y2 E W3 A98459 Fig 13 Single Speed Air Conditioner with Variable Speed FK4D FV 40FK Fan Coil A98464 24 VAC HOT HEAT STAGE 1 24 VAC COMM COOL STAGE 1 FAN R G W W1 Y...

Page 9: ...n Coil A98466 24 VAC HOT 24 VAC COMM FAN COOL HEAT STAGE 1 HEAT STAGE 2 R Y Y2 R C C C R MODEL HP THERMOSTAT EASY SELECT TERMINAL BOARD SINGLE SPEED HEAT PUMP J1 JUMPER J2 JUMPER See notes 7 8 and 11...

Page 10: ...eat Refer to indoor equipment Installation Instructions for proper setup 5 Refer to outdoor equipment Installation Instructions for latent kit requirements if any 6 Terminals marked with may not be pr...

Page 11: ...s the model configuration via the following 2 digit code AC 1 speed air conditioner HP 1 speed heat pump A2 2 speed air conditioner H2 2 speed heat pump ERROR CODES If the thermostat cannot properly r...

Page 12: ...AC Configuration 6 Cooling Lockout Off or On factory default Off 7 Zoning Selection Off or On factory default Off 8 Auxiliary Heat Lockout Off or 5 55 F factory default Off 9 N A 10 O Reversing Valve...

Reviews: