background image

TO SELECT:

1. Enter configuration mode (if not already there).

2. Use up and down buttons to display Option 07. The SET

icon should be off.

3. Press MODE button once. The SET icon will come on. The

display now shows Option 07 setting.

4. Use up and down buttons to move between available Option

07 choices of ON or OF. Factory default is OF.

5. Press MODE button again to return to Option 07. The SET

icon will now be off.

6. Use up and down buttons to select another Option, or press

FAN button to exit configuration mode.

H.

Option 08—High Ambient Auxiliary Heat Lockout

Present in HP and 2S models only when configured as a heat
pump. Outdoor temperature sensor must be attached. This selec-
tion allows lockout of any electric heat (W output) when outdoor
temperature is above a selected temperature. Temperatures of 5° to
55°F (or equivalent values in C) can be selected. Feature can be
disabled by selecting OFF. Emergency heat (EHEAT mode)
always overrides this feature.

TO SELECT or ADJUST:

1. Enter configuration mode (if not already there).

2. Use up and down buttons to display Option 08. The SET

icon should be off.

3. Press MODE button once. The SET icon will come on. The

display now shows Option 08 setting.

4. Use up and down buttons to move between available Option

08 choices of OF, or 5 through 55 in 5° steps. Factory
default is OF.

5. Press MODE button again to return to Option 08. The SET

icon will now be off.

6. Use up and down buttons to select another Option, or press

FAN button to exit configuration mode.

I.

Option 10 — O (reversing valve) On with Heat or Cool

Selection

This selection is only available on HP and 2S model thermostats
when HP is selected via Option 05. This selection determines
whether the reversing valve is energized in the heating or cooling
mode. Factory default is C, energized in cooling. Use up and down
buttons to change between H and C.

TO SELECT:

1. Enter configuration mode (if not already there).

2. Use up and down buttons to display Option 10.

3. Press MODE button once. The SET icon will come on. The

display now shows Option 10 setting.

4. Use up and down buttons to move between available Option

10 choices of H (heat) or C (cool). Factory default is C.

5. Press MODE button again to return to Option 10. The SET

icon will now be off.

6. Use up and down buttons to select another Option, or press

FAN button to exit configuration mode.

J.

Option 13—Room Temperature Offset

This option allows calibration (or deliberate miscalibration) of
room temperature sensor. There are various reasons why the home
owner may want to have displayed temperature adjusted to a
higher or lower value. The selected number is the number of
degrees, plus or minus, which will be added to the actual
temperature. The number can range between -5 and +5. Factory

default is 0. This adjusted value will be used as actual temperature
for both display and control action. For example, if 2 is selected,
72°F actual will read 74°F. If setpoint is 72, the room will control
to an actual value of 70 which will be displayed and acted upon as
if it were 72. The effect is that a positive number selection will
make the room temperature lower and vice versa. This thermostat
is factory calibrated within an accuracy of plus or minus 1°F, so
this adjustment will provide the best accuracy when set to 0.

TO SELECT:

1. Enter configuration mode (if not already there).

2. Use up and down buttons to display Option 13. The SET

icon should be off.

3. Press MODE button once. The SET icon will come on. The

display now shows Option 13 setting.

4. Use up and down buttons to move between available Option

13 choices of -5 t5 in 1° steps. Factory default is
0.

5. Press MODE button again to return to Option 13. The SET

icon will now be off.

6. Use up and down buttons to select another Option, or press

FAN button to exit configuration mode.

K.

Option 15—Auto Mode On/Off Selection

This options allows the installer to enable or disable AUTO mode
(automatic changeover between heat and cool). When disabled,
AUTO icon does not appear when successive presses of MODE
button are used to move between OFF, HEAT, and EHEAT (in
heat pump systems). Factory default is ON (AUTO mode enabled).

TO SELECT:

1. Enter configuration mode (if not already there).

2. Use up and down buttons to display Option 15. The SET

icon should be off.

3. Press MODE button once. The SET icon will come on. The

display now shows Option 15 setting.

4. Use up and down buttons to move between available Option

15 choices of ON or OF. Factory default is ON.

5. Press MODE button again to return to Option 15. The SET

icon will now be off.

6. Use up and down buttons to select another Option, or press

FAN button to exit configuration mode.

L.

Option 18 — Backlight Configuration

This function is only available when the thermostat is operating
from full power via R and C. It is not available when the
thermostat operates from batteries. In OF (off) mode, this function
is disabled. The thermostat backlight will normally be off. It turns
on with any button press and stays on for 10 seconds in between
button presses. In ON mode, this function is enabled. The
thermostat backlight will normally be on and dim in appearance.
The backlight becomes brighter with any button press and remains
bright for 10 seconds. Factory default is OF.

TO SELECT:

1. Enter configuration mode (if not already there).

2. Use up and down buttons to display Option 18. The SET

icon should be off.

3. Press MODE button once. The SET icon will come on. The

display now shows Option 18 setting.

4. Use up and down buttons to move between available Option

18 choices of ON or OF. Factory default is OF.

5. Press MODE button again to return to Option 18. The SET

icon will now be off.

—4—

Summary of Contents for TSTATBBN2S01-C

Page 1: ...lication Models are AC 1 stage cool 1 stage heat for AC systems only HP 1 stage cool 2 stage heat for either HP or AC with 2 stage heat 2S 2 stage cool 2 stage heat for 2 speed AC systems or 2 stage c...

Page 2: ...on page 11 for explanation IV SET THERMOSTAT CONFIGURATION Configuration options are intended to be selected at installation and are normally not modified by the home owner These options are not disc...

Page 3: ...D Option 04 G Fan On With W W1 Output This selection determines whether the G fan output is to be ON or OFF when any W furnace or strip heat output is ON Most furnaces and fan coils manage their own b...

Page 4: ...ween 5 and 5 Factory default is 0 This adjusted value will be used as actual temperature for both display and control action For example if 2 is selected 72 F actual will read 74 F If setpoint is 72 t...

Page 5: ...ler test will be initiated by pressing the fan button for 20 seconds 15 seconds will enter installer setup InS will appear on the screen and the SERVICE icon will be illuminated In installer test mode...

Page 6: ...R CONDITIONER See notes 6 10 and 11 Y G W2 E W3 HEAT STAGE 1 FAN A98453 Fig 2 Single Speed Air Conditioner with Single Stage Furnace A04006 24 VAC HOT 24 VAC COMM HEAT STAGE 1 COOL STAGE 1 FAN R C G W...

Page 7: ...ED AIR CONDITIONER See notes 2 4 6 10 and 11 Y G O W2 B W2 E W3 A98455 Fig 9 Two Speed Air Conditioner with 2 Stage or Variable Speed Furnace A04010 24 VAC HOT 24 VAC COMM HEAT STAGE 1 COOL STAGE 2 FA...

Page 8: ...2 4 5 6 8 10 and 11 Y G O W2 B W2 R Y2 E W3 A98459 Fig 13 Single Speed Air Conditioner with Variable Speed FK4D FV 40FK Fan Coil A98464 24 VAC HOT HEAT STAGE 1 24 VAC COMM COOL STAGE 1 FAN R G W W1 Y...

Page 9: ...n Coil A98466 24 VAC HOT 24 VAC COMM FAN COOL HEAT STAGE 1 HEAT STAGE 2 R Y Y2 R C C C R MODEL HP THERMOSTAT EASY SELECT TERMINAL BOARD SINGLE SPEED HEAT PUMP J1 JUMPER J2 JUMPER See notes 7 8 and 11...

Page 10: ...eat Refer to indoor equipment Installation Instructions for proper setup 5 Refer to outdoor equipment Installation Instructions for latent kit requirements if any 6 Terminals marked with may not be pr...

Page 11: ...s the model configuration via the following 2 digit code AC 1 speed air conditioner HP 1 speed heat pump A2 2 speed air conditioner H2 2 speed heat pump ERROR CODES If the thermostat cannot properly r...

Page 12: ...AC Configuration 6 Cooling Lockout Off or On factory default Off 7 Zoning Selection Off or On factory default Off 8 Auxiliary Heat Lockout Off or 5 55 F factory default Off 9 N A 10 O Reversing Valve...

Reviews: