background image

T1--NAC

T1--NHP

LEGACY LINE--RNC

NON--PROGRAMMABLE THERMOSTAT

Installation Instructions

Designed and Assembled

in the USA.

US patents: US20060165149 A1, USD578026 SI, US6205041 B1

A07110

Legacy Line---RNC Non---Programmable Thermostat

NOTE

: Read the entire instruction manual before starting the

installation.

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . .

INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 1 — Thermostat Location

2

. . . . . . . . . . . . . . . . . . . . . . . .

Step 2— Install Thermostat

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 3 — Set Thermostat Configuration

2

. . . . . . . . . . . . . . . . .

Step 4 — Thermostat Operation

3

. . . . . . . . . . . . . . . . . . . . . . . .

Step 5 — Check Thermostat Operation

3

. . . . . . . . . . . . . . . . . .

WIRING DIAGRAMS

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified
installer or agency muse use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these

instructions thoroughly and follow all warnings or cautions
included in literature and attached to the unit. Consult local

building codes and the current editions of the National Electrical

Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical

Code CSA C22.1.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in the instructions or

manuals, be alert to the potential for personal injury.
Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the safety--alert symbol.

DANGER

identifies the most serious hazards which

will

result in

severe personal injury or death.

WARNING

signifies a hazard

which

could

result in personal injury or death.

CAUTION

is used

to identify unsafe practices which

may

result in minor personal

injury or product and property damage.

NOTE

is used to highlight

suggestions which

will

result in enhanced installation, reliability, or

operation.

INTRODUCTION

The Legacy Line--RNC Series thermostat is an electronic 24VAC,
non--programmable, manual changeover wall mount thermostat.

This thermostat uses a single setpoint to maintain and control room
temperature in both the heating and air conditioning modes. The

thermostat is designed to ma/-- 2

_

F accuracy. No batteries

are required; temperature, fan, mode, and installer configuration
settings are preserved with power off.

INSTALLATION CONSIDERATIONS

Air Conditioner Model

T1--NAC, Legacy Line--RNC Series Model air conditioner
thermostat, may be wired with or without connecting a common

wire between the indoor equipment and the thermostat. However, it
is recommended to use a common wire whenever possible.

Without a common wire this thermostat becomes “power stealing.”

This means it will need to steal a small amount of power from the
equipment to which it is connected.

NOTE

: Not all HVAC equipment is compatible with power

stealing type thermostats. All Bryant equipment is directly
compatible with this thermostat except the Thermostat Conversion
Kit, Part #TSTATXXCNV10. For all non--Bryant equipment,
consult the system equipment Installation Instructions before
applying this thermostat in a power stealing manner.

Heat Pump Model

T1--NHP, Legacy Line--RNC Series Model heat pump thermostat,
is compatible with all Bryant heat pump systems. It is NOT power

stealing and MUST have both the R and C terminals connected to

operate properly. This thermostat uses a green LED to indicate
auxiliary heat and emergency heat operation.

Summary of Contents for LEGACY LINE-RNC T1-NAC

Page 1: ...e words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies a hazard which could result in personal...

Page 2: ...conditioner model 1 stage heat 1 stage cool or HP or PH for heat pump model 2 stage heat 1 stage cool Step 3 Set Thermostat Configuration Configuration options allow the installer to configure the th...

Page 3: ...the output is turned on e g if Y output is turned on for 9 minutes and then satisfies it cannot turn back on for another 6 minutes regardless of demand However pressing UP and FAN buttons simultaneous...

Page 4: ...al Installation Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations E2012 Bryant Heating Cooling Systems 731...

Page 5: ...e seconds after the last button press the display returns to the room temperature and the SET TEMP icon turns off TROUBLESHOOTING What if there is a green light on in the upper corner of the display a...

Page 6: ...2...

Page 7: ...mpany s exclusive obligations under this warranty for a product failure This limited warranty is subject to all provisions conditions limitations and exclusions listed below and on the reverse if any...

Page 8: ...AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installi...

Reviews: