MODEL 598A

 

TWO-SPEED PLUS
CENTRAL AIR CONDITIONER

 

USER’S INFORMATION MANUAL

 

 

NOTE TO
INSTALLER:
This manual
must be
left with the
equipment user.

 

Summary of Contents for 598A

Page 1: ...MODEL 598A TWO SPEED PLUS CENTRAL AIR CONDITIONER USER S INFORMATION MANUAL NOTE TO INSTALLER This manual must be left with the equipment user ...

Page 2: ...nnected by refrigerant tubes as shown in Fig 1 Each unit has a rating plate affixed to it A rating plate provides necessary information for specific identification of a unit You should familiarize yourself with the product model and serial numbers listed on each rating plate Record them for future reference on the last page of this booklet IMPORTANT FACTS To better protect your investment and to e...

Page 3: ... cleaners and or humidifi ers offer the added benefits of having the air continuously cleaned year round and humidified during the winter season Ventilation A system equipped with a heat or energy recovery ventilator offers the advantage of exhausting stale air from the home and allowing fresh air in from the outdoors while minimizing heat loss Zoning Your system may also be equipped with a zoning...

Page 4: ...ings on your home s heating and cooling NOTE Your 2 speed air conditioning systemhas severalspecialfeaturesbuiltin to protect the unit 5 MINUTE TIME DELAY Unit will delay operation upon initial start up or short cycling of the indoor thermostat 1 MINUTE TIME DELAY When changing speeds from low to high or high to low there is a 1 minute time delay During the speed change delay the outdoor fan will ...

Page 5: ...could requireremovingthecoil Donotattempt this yourself OUTDOOR COIL If grass clippings leaves shrubbery and debris are kept away from the outdoor unit minimal care should keep the sys tem functioning properly For proper drainage debris must be removed period ically from the base pan However if the outdoorcoilbecomesdirty useavacuum cleaner with soft brush attachment to clean the exterior surface ...

Page 6: ...filter s Replacement or cleaning as required Inspection and cleaning of the blower wheel housing and motor Inspection and if required cleaning of indoor and outdoor coils Inspection of the indoor coil drain pan plus the primary and secondary drain lines If supplied the auxiliary drain pan and line should be inspected at this time Service should include cleaning if required A check of all electrica...

Page 7: ...7 ...

Page 8: ...o Model No Serial No MODULAR INDOOR UNIT if Applicable Blower Product No Model No Serial No Coil Product No Model No Serial No Heater Product No Model No Serial No ACCESSORIES Product No Product No Product No Product No Product No Cancels OM01 16 OM01 18 1998 Bryant Heating Cooling Systems 7310 W Morris St Indpls IN 46231 Printed in U S A Catalog No 5359 804 11 98 ...