8
natural bristle) or vacuum cleaner with brush attachment. See Fig.
11.
Gently stroke the ionization pins on the top plane of each bar with
enough brush depth to hit front and back tips of the points in the
ionization array. Use a gentle back and forth brushing motion to
clean any small accumulations from the tips of the points. If
desired, use vacuum cleaner with brush attachment to gently
vacuum the frame and components of enhancement module.
Reinstall the safety screen.
Do not operate the unit without the
Safety Screen.
Slide in enhancement module.
Reconnect power cord.
Replace the purifier door.
Turn the purifier switch to the on position.
Turn heating and cooling system power on.
30°
POINTS ARE SHARP! BE VERY CAREFUL DURING CLEANING.
Tip of point with residue
Tip of point after cleaning
A06671
Fig. 11 -- Removal of Deposits from Ionization Pins
TROUBLESHOOTING
SAFETY HAZARD
Failure to follow this caution may result in personal injury or
equipment damage.
The following instructions are for use by qualified personnel
only.
CAUTION
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
The following procedures will expose electrical components.
Disconnect power between checks and proceed carefully.
!
WARNING
The purifier is equipped with a power indicator light located on the
door (see Fig. 10). This power indicator light will illuminate when
the purifier door is installed, the power switch is in the on position,
AND the furnace blower is running. If the power indicator light is
not illuminated, follow the troubleshooting steps below.
See Table 1.
GAP
A
A