Technical data
and start-up
BDC546
28
6.7
Safety concept for vehicle installation
INFORMATION
This safety concept is a recommendation of BRUSA Elektronik AG and is a general requirement for
the safe operation of electric vehicles!
6.7.1
General interlock function
The interlock switches (1) are closed if the respective interlock conditions of the individual devices are met (closed
service cap, HV connections plugged-in...). The interlock evaluation system of the PDU switches the 12 V supply
voltage (2) of the HV contactors (4) in the battery if the interlock circuit is closed. The emergency off switch (3) also
disconnects the 12 V supply voltage of the HV contactors (4). The second interlock switch (5) of the insulation
monitoring unit disconnects the interlock circuit if an error is detected at the HV insulation.
Summary of Contents for BDC546
Page 27: ...27 Technical data and start up BDC546 6 6 Vehicle installation basic principle ...
Page 82: ...Technical data and start up BDC546 82 16 Attachments 16 1 Cable fitting ...
Page 83: ...83 Technical data and start up BDC546 ...
Page 84: ...Technical data and start up BDC546 84 ...
Page 85: ...85 Technical data and start up BDC546 ...
Page 86: ...Technical data and start up BDC546 86 16 2 Cable lugs ...