10
Installation manual (1.4)
© 2019 Brunner GmbH
The Iron Dog 06 can also be installed without
leveling feet. In this case the Iron Dog 06 should be
placed on a base from mineral, non-combustible
material.
In this base, the area marked in the illustration
must be kept open, in order to guarantee sufficient
combustion air supply. The combustion air must be
able to flow freely to this area.
Illustr. 5: Combustion air supply
9
DISTANCES
The floor area (BB) under and in front of the Iron Dog must consist of an incombustible cover. Details can be
found in the technical data.
The given safety distances guarantee that at adjacent construction parts (wall) no temperatures
> 85°C can appear. If necessary keep bigger distances towards delicate objects and furniture.
If a radiation shield (SB) is placed at the back wall, the Iron Dog can be placed at a distance
“B” from the back wall. If in addition to the radiation shield "SB" also a ventilated double-walled
wall protection shield is used, the distance to the wall can be reduced to "W" (not shown in the
illustration. Without radiation shield the minimum distance "O" should be kept. The safety distance
of the smoke pipe to the ceiling of the building “A” depends on the material used for the ceiling.