In case of narrow distances to the scrapers, rotate the scraper unit until it is positioned transversely to
the machine rotation direction. Very small distances may require raising of the scrapers to allow
removal of the perforated plate.
Fig. 27
: Scraper unit placed transversely to the plate
After removal of the perforated plate, loosen the hexagon head screw on the scraper unit. Rotate
counterclockwise out of the bayonet lock and pull it off the drive shaft from below.
NOTE!
-
For storage and cleaning, the loading unit must be blocked with the hook.
Insertion of the plastic plate: ensure that the plate is inserted correctly. The side with the angled corner
must be placed on the hinge side of the hood.
Fig. 28