The IFS 125M spectrometer is a mobile high resolution FT-IR spectrometer and has
been designed to perform field operation and precise stratospheric analysis, generate
atmospheric emission studies, and remotely monitor atmospheric pollutants.
Atmospheric pollution can be measured in transmittance, using the sun as active IR
radiation source.
For stratospheric transmittance measurements, the solar radiation is collected by a solar
tracker system, which automatically follows the position of the solar source. It has been
proven that this technique can also be used with the moon as IR source, despite the
orders of magnitude lower radiation power.
2.1
Design
• Compact optics housing
• Detachable interferometer scanning arm
• Purgeable enclosure for interferometer, scanner and detectors
2.2
Optics
• Spectral range starting from the mid-infrared (MIR) region at 450 up to the ultra-
violet range of 45000 cm
-1
• Spectral resolution of 0.008 cm
-1
(optionally: 0.0035 cm
-1
) in the MIR region
• Resolving power of >10
6
• Up to 2 internal detectors
• Permanently aligned, 30° cube-corner mirror interferometer
2.3
Electronics
The spectrometer is equipped with a mobile (separate) electronics unit which uses
Ethernet connectivity, and a 24 V DC power supply. Any modern data system (PC work-
station, laptop etc.), with the OPUS spectroscopy software installed, can be used to con-
trol the spectrometer and perform data processing.
Analog to Digital Conversion (ADC) electronics allow high resolution measurements
from the MIR through the near-infrared (NIR) region, up to the visible and ultraviolet
(VIS/UV) spectral ranges.
Functions such as checking measurement parameters allow fast and reliable FT-IR
spectroscopic measurements. Optical components, e.g, source and beamsplitter, are
electronically coded so that the spectrometer firmware can recognize them.
In addition, the permanent online check of spectrometer components facilitates error
diagnostics and maintenance.
Summary of Contents for IFS 125M
Page 1: ...IFS 125M User Manual 1015996 ...
Page 8: ...8 IFS 125M User Manual Bruker Optik GmbH Table of Contents ...
Page 14: ...14 IFS 125M User Manual Bruker Optik GmbH Introduction 1 ...
Page 30: ...30 IFS 125M User Manual Bruker Optik GmbH Installation 3 ...
Page 66: ...66 IFS 125M User Manual Bruker Optik GmbH Operation 5 ...
Page 170: ...170 IFS 125M User Manual Bruker Optik GmbH Web Interface 8 ...
Page 196: ...196 IFS 125M User Manual Bruker Optik GmbH Connection Ports 10 ...
Page 202: ...202 IFS 125M User Manual Bruker Optik GmbH Spare Parts B ...
Page 208: ...208 IFS 125M User Manual Bruker Optik GmbH Dimensional Drawings D ...
Page 214: ...214 IFS 125M User Manual Bruker Optik GmbH Firmware Update E ...
Page 222: ...222 IFS 125M User Manual Bruker Optik GmbH Addresses G ...
Page 226: ...226 IFS 125M User Manual Bruker Optik GmbH Index ...