CHAPTER
7
Troubleshooting
41
Fig.7.2
Remote
Station
client
showing
connection
settings
2) Check to see if the IP addresses for the Vehicle and Ground Stations are both within
the correct family of IP addresses.
Note:
The Subnet mask must be set to
255.255.255.X
.
A Subnet mask
255.255.0.0
will
not
work!
7.5
Troubleshooting
the
Weather
Station
The weather station is a plug and play design utilizing Power over Ethernet (PoE) for a
single-cable installation.
If it is not functioning or functioning incorrectly, try to isolate the problem in the
following manner:
Are
there
values
visible
on
the
Ground
Station
PC?
If there are values present and they are incorrect, then check that the orientation of the
weather station is correct. There is an arrow underneath the body of the sensor that
points north, this must be aligned with true north unless otherwise configured in the
unit’s software.