Effectivity: 914 Series
Rev. 0
BRP-Rotax
Page 4-7
August 01 2019
4.6) Re-Start during flight
If the propeller continues to rotate during flight by windmilling,
but the speed is not sufficient to start the engine, the electric
starter can be used. It is not required to wait until the propeller
stops rotating.
4.7) Exceeding max. admissible engine speed
Exceeding engine
speed
Reduce the engine speed. Any exceeding of the max. admissi-
ble engine speed must be entered by the pilot into logbook,
stating the exact time and duration of engine over speed.
• A maintenance inspection should be carried out
4.8) Exceeding of max. admissible cooling system temperature
ATTENTION
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
4.8.1) Exceeding of max. admissible cyl. head temperature
ATTENTION
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
Cylinder head
temperature max.
Applicable for engine S/N without Suffix -01.
• Any exceeding of the max. admissible cylinder head temper-
ature must be entered by the pilot into the logbook, stating
duration and extent of over-temperature condition.
• Carry out an unscheduled maintenance check according to
Maintenance Manual Line chapter 05-50-00.
4.8.2) Exceeding of max. admissible coolant temperature
ATTENTION
Reduce engine power setting to the minimum necessary and
carry out precautionary landing.
Coolant tempera-
ture max.
Applicable for engine S/N with Suffix -01.
Summary of Contents for ROTAX 914 Series
Page 6: ...Page INTRO 2 August 01 2019 BRP Rotax Effectivity 914 Series INTENTIONALLY LEFT BLANK...
Page 66: ...Page 6 2 August 01 2019 BRP Rotax Effectivity 914 Series INTENTIONALLY LEFT BLANK...
Page 86: ...Page 8 4 August 01 2019 BRP Rotax Effectivity 914 Series INTENTIONALLY LEFT BLANK...
Page 88: ...9 1 Form Figure 1 Form Page 9 2 August 01 2019 BRP Rotax Effectivity 914 Series Rev 0...
Page 93: ......
Page 94: ......
Page 95: ......