86
Gauge Flashes Four Dashes
1. If the
I-Command
digital display flashes four dashes (– – – –) it indicates
the gauge is not receiving signal from one or more devices.
2. A Network Test Kit, P/N 765023 is available to assist in troubleshooting
network problems. If desired, order the tester kit through your dealer.
Troubleshoot network problems using process of elimination.
•Make sure devices are configured. See “Advanced Setup and Opera-
tion” on page 57.
•If multiple displays are flashing, check common items such as cables
and tees.
•Remove components from the network
one at a time
to isolate which
one may have failed.
•Look for damaged parts. Check connectors for corrosion.
•Swap known good components (sensor, cables or tees) to isolate the
faulty component.
•Reconnect the good component to the network and the remove the next
one in line.
•Continue this process for each device, cable or tee connector on the
network until the faulty part is found.
Note:
Once components are reconnected, if the digital display continues to
flash, turn power to the network OFF and back ON to reset the gauge(s).
M E N U
DOWN
UP
EXIT
PAGES
ENTER
WTR: T
ALR:V
BATT:V
WTR:P
Volts
Volts
°F
psi
– – – –
– – – –
13.6 56.2
20 70
10 35
0 0
20 70
10 35
0 0
x10
+
+
-
-
-
+
+
L
L
L
H
H
H
S
+
N2K Bus
Tester
DEVICED
E
V
IC
E
BUSS
BUSS
1
2
Summary of Contents for I-Command Evinrude Etec Series
Page 1: ...User s Guide ...
Page 2: ...http www boat fuel economy com evinrude icommand for sale ...
Page 6: ...4 Installation ...
Page 17: ...15 Basic Setup and Operation ...
Page 30: ...28 Setup Notes ...
Page 31: ...29 Customizing Displays ...
Page 58: ...56 Customizing Notes ...
Page 59: ...57 Advanced Setup and Operation ...
Page 86: ...84 Advanced Setup Notes ...
Page 87: ...85 Troubleshooting ...
Page 94: ...92 Troubleshooting Notes ...
Page 95: ...93 Updating Gauge Software ...
Page 102: ...100 Software Notes ...
Page 103: ...101 Reference Information ...
Page 112: ...110 Owner s Notes ...
Page 113: ... 354598 ...