![BRP Evinrude E-TEC Manual Download Page 111](http://html1.mh-extra.com/html/brp/evinrude-e-tec/evinrude-e-tec_manual_2820522111.webp)
111
Electrical and Ignition
Remote Control Switch Tests
6
IMPORTANT:
All wiring must be disconnected
from the switch before proceeding with this test.
Disassemble the remote control and remove the
neutral start switch.
Connect one meter lead to each terminal of the
switch.
•
Meter must indicate continuity when the plunger
is depressed
•
Meter must indicate no continuity when the
plunger is released.
Replace switch if results are incorrect.
Emergency Stop Switch Test
This switch can be part of the key switch or
installed as a separate switch. Either style con-
nects the “M” terminals of the key switch.
The emergency stop switch function grounds the
stop circuit wire (black/yellow) when the lanyard
clip is removed. One “M” terminal is the ground
wire (black) and one “M” terminal is the stop circuit
wire (black/yellow).
Install the clip on the emergency stop switch or
key switch. Start the outboard. Pull the clip from
the switch. The outboard must stop running.
TYPICAL
1.
Plunger
2.
Neutral start switch
3224
1
2
1.
Lanyard and clip assembly
2.
Emergency stop switch, separate from key switch
3.
Stop circuit wire (black/yellow)
4.
Ground wire (black)
010305
B
M
M
C
A
S
1
2
3
4
Summary of Contents for Evinrude E-TEC
Page 232: ...Powerhead Powerhead Views 232 2 Cylinder Front 008160...
Page 233: ...Powerhead Powerhead Views 233 10 2 Cylinder Rear 010509...
Page 234: ...Powerhead Powerhead Views 234 2 Cylinder Top 010511...
Page 235: ...235 Powerhead Powerhead Views 10 2 Cylinder Top Rope Start Models 008186...
Page 238: ...Powerhead Powerhead Views 238 3 Cylinder Front 008166...
Page 239: ...239 Powerhead Powerhead Views 10 3 Cylinder Rear 010515...
Page 240: ...Powerhead Powerhead Views 240 3 Cylinder Top 010517...
Page 326: ...S 326...