Evinrude ICON II Remote Control System
System Settings and Diagnostics
230
Remote Control Monitor
Select the
Monitor
button to view certain power
faults and remote control functions. On-screen
indicators will illuminate when the related function
on the remote control is activated.
Remote Control Faults
Select the
Faults
button to view any remote con-
trol fault codes.
ICON II
System NEUTRAL Idle Mode
The following conditions will cause the
ICON II
system to enter NEUTRAL idle mode:
•
Remote control lever sensor failure
•
Foot throttle sensor failure
•
Loss of communication with the
EMM
The
EMM
:
Remote Control Software
Select the
Software
button to upload software to
the remote control. Press the
Load Software
but-
ton and follow the on-screen prompts.
Remote Control Monitor Screen
009388
Remote Control Faults Screen
009387
Activates NEUTRAL idle
mode
Stores remote control fault code between
1 and 12; or, 21, 24, 27, or 30.
Engine Monitor: CHECK ENGINE display ON
Remote Control Software Screen
009390
Summary of Contents for E 250 L HO AG B
Page 271: ...Powerhead Powerhead Views 271 11 Powerhead Views Starboard 009375...
Page 272: ...272 Powerhead Powerhead Views Port Non DPS Models 009406...
Page 273: ...Powerhead Powerhead Views 273 11 Port DPS Models 009374...
Page 274: ...274 Powerhead Powerhead Views Rear 200 225 250 HP Models 009407...
Page 275: ...Powerhead Powerhead Views 275 11 Rear 250 H O 300 HP Models 009376...
Page 276: ...276 Powerhead Powerhead Views Front Frame Removed 009379...
Page 277: ...Powerhead Powerhead Views 277 11 Front Frame Installed 009378...
Page 416: ...S 416...