![BRÖTJE NEOP 300 Assembly Instructions Manual Download Page 27](http://html.mh-extra.com/html/brotje/neop-300/neop-300_assembly-instructions-manual_2820065027.webp)
6 Service
The first filling of the granulate lasts for at least one year. To ensure
smooth function, the neutralisation unit must be inspected once per year
and serviced if necessary.
See
In addition to the information in these assembly instructions, the
Installation Manual
of the gas-fired condensing boiler must be
observed.
6.1
Function check
1. Check level.
If the level is under the display of the filling height label, granulate
must be added.
Important
Neutralisation can only be done if the granulate is flowing.
The granulate level must always be over the condensate
level!
2. Measure the pH value with indicator strips.
With a pH value < 6.5, the neutralisation unit must be serviced.
6.2
Performing service
1. Disconnect the pump from the power supply.
2. Remove the inlet and outlet connections.
3. Remove the neutralisation pipe out of the brackets.
4. Open the hose clamp on the service cover and remove the service
cover.
5. Pour out granulate completely into a suitable container (e.g., bucket).
6. Loosen clumps of granulate.
7. Clean neutralisation pipes with water.
Caution
Do not use sharp objects during cleaning, since this could damage
the housing!
8. Fill granulate to the filling height label in the vertically positioned
neutralisation pipes.
Important
In a horizontal position must be a clearance of min. 4 cm
maintained above the granulate.
9. Reattach service cover and fasten with hose clamp.Pay attention to
the arrow mark on the service cover for correct positioning.
10. Reconnect the inlet and outlet connections.
11. Reconnect the pump to the power supply.
12. Pull off the air hose and check for function.
13. Check all connections for leaks.
14. Attach
Service
label clearly visible on the used gas-fired condensing
boiler.
15. Log service in the
Proof of Service
(see
appendix
)
6.3
Disposal of the granulate
The granulate disposes of itself automatically. The acids contained in the
condensate combine to form fully soluble salts, which are widely used in
nature. The granulate is approved for DHW treatment. Granulate residue
can be thermal disposed of in the normal household rubbish. If this is not
ensured, the type of disposal must be obtained from the competent
authority.
Fig.22
Open the neutralisation pipe
RA-0001684
4
8
A
6 Service
en
7311618 - 04 - 20022020
27
Summary of Contents for NEOP 300
Page 15: ...7 Anhang 7 1 Wartungsnachweis RA 0001685 7 Anhang de 7311618 04 20022020 15 ...
Page 16: ...de 7 Anhang 16 7311618 04 20022020 ...
Page 28: ...7 Appendix 7 1 Proof of Service RA 0001685 en 7 Appendix 28 7311618 04 20022020 ...
Page 41: ...7 Annexes 7 1 Preuve de l entretien RA 0001685 7 Annexes fr 7311618 04 20022020 41 ...
Page 42: ...fr 7 Annexes 42 7311618 04 20022020 ...
Page 55: ...7 Appendice 7 1 Attestato di Manutenzione RA 0001685 7 Appendice it 7311618 04 20022020 55 ...
Page 56: ...it 7 Appendice 56 7311618 04 20022020 ...
Page 69: ...7 Bijlage 7 1 Servicebewijs RA 0001685 7 Bijlage nl 7311618 04 20022020 69 ...
Page 70: ...nl 7 Bijlage 70 7311618 04 20022020 ...
Page 84: ...es 7 Apéndice 84 7311618 04 20022020 ...
Page 98: ...pl 7 Dodatek 98 7311618 04 20022020 ...
Page 110: ...7 Priedas 7 1 Techninės priežiūros žurnalas RA 0001685 lt 7 Priedas 110 7311618 04 20022020 ...
Page 123: ...7 Приложение 7 1 Журнал обслуживания RA 0001685 7 Приложение ru 7311618 04 20022020 123 ...
Page 124: ...ru 7 Приложение 124 7311618 04 20022020 ...
Page 125: ...7 Приложение ru 7311618 04 20022020 125 ...
Page 126: ...ru 7 Приложение 126 7311618 04 20022020 ...
Page 128: ...August Brötje GmbH 26180 Rastede broetje de 7311618 04 20022020 ...