- 7 -

III

. Setting the Scanner Adjustment and Test Mode

With this equipment, because each scanner has its own individual characteristics and these are stored
in the memory element in the main PC board assembly, scanner adjustment and testing should always
be carried out if only the main PC board assembly is being replaced, or if the scanner (B5N-1771) is
being replaced. In any other case, the adjustment has already been made at the factory before the unit
is shipped, and does not need to be done again.

[Items Required for Adjustment]

Adjusting the scanner requires that the test picture be read. Copy the test picture found on page 8, and cut
out the picture along the dotted lines.

[Starting Up the Test Mode]

Pressing the main power switch while holding down the highest and lowest of the five operation switches
puts the scanner in the Adjustment and Test Mode.

[Adjusting the Scanner]

Set the test picture on the glass plate (see Fig. 1).

Press the  SCAN  button. (The buzzer will sound once.)

ƒ

Scan the test picture while holding down the scanner button.

Press the  SCAN  button. (The buzzer will sound twice.)

Scan the test picture once again while holding down the scanner button.

If there have been no internal problems with the adjustment at the point where step 

 is completed, the

power supply will shut off automatically.
If a message reading "No original found" is displayed after step 

ƒ

 or step 

 , press the

button and repeat the procedure starting from step 

. If the above message appears, the test picture

may not have been placed on the glass plate in the correct position.

Fig. 1

CORRECT
    &REDO

www.promelectroavtomat.ru

Summary of Contents for SCANNERII

Page 1: ...SERVICE MANUAL PARTS LIST SCANNERII 12 1997 www promelectroavtomat ru ...

Page 2: ...ations for the purpose of improvements Contact manufacturer or local sales company for information concerning such changes l CAUTION l 1 Always use rubber gloves when handling printed circuit boards and never touch the metal portion of a printed circuit board with bare hands 2 Keep your body earthed in order to avoid generating static electricity 3 Pack printed circuit boards in aluminum foil and ...

Page 3: ... 2 I Main Configuration 1 Main Components www promelectroavtomat ru ...

Page 4: ... 3 2 Control System Block Diagram www promelectroavtomat ru ...

Page 5: ... on the unit The language mode screens change in the following order I II III This mode ends if JAPANESE ENGLISH or KOREAN is chosen When screen II of the language mode is displayed select the language with and then press ENTER If NEXT PAGE is pressed another screen showing more languages is displayed www promelectroavtomat ru ...

Page 6: ...rd assembly and take out the assembly Disconnect the scanner connector from the main PC board assembly Remove the cord guide from the main body of the scanner and disconnect the scanner connector from the main body Remove the four screws that secure the LCD module to the main body of the scanner and take off the LCD module ˆ Remove the four screws that secure the battery holder to the main body an...

Page 7: ... 6 www promelectroavtomat ru ...

Page 8: ...ode Pressing the main power switch while holding down the highest and lowest of the five operation switches puts the scanner in the Adjustment and Test Mode Adjusting the Scanner Set the test picture on the glass plate see Fig 1 Press the SCAN button The buzzer will sound once ƒ Scan the test picture while holding down the scanner button Press the SCAN button The buzzer will sound twice Scan the t...

Page 9: ... 8 Test picture Copy the picture and cut along the dotted lines The size should be W125 mm H143 mm www promelectroavtomat ru ...

Page 10: ...eing used Other Points to Check Check carefully Replace the fuse First check to see why the fuse has blown and correct the problem ƒ Replace the terminal plate assembly Replace the AC adaptor Replace the main PC board assembly The LCD display does not function correctly Has the LCD contrast adjustment knob been adjusted Have the LCD module and the main PC board assembly been connected or are there...

Page 11: ...the image correctly Has the scanner been adjusted correctly Check other points carefully Adjust the scanner See page 7 for information on scanner adjustment Replace the main PC board assembly or the Scanner B5N 1771 Data cannot be stored on the original card Can the data be stored properly if a different original card assembly is used Check other points carefully Replace the main PC board assembly...

Page 12: ... 11 www promelectroavtomat ru ...

Page 13: ... 12 www promelectroavtomat ru ...

Page 14: ...Guide cover panel XA0293001 Guide cover panel BabyLock 15 X59851001 Holder 16 X59852001 Spring 17 X59853000 Rubber cushion 18 XA3901001 Main PC board assembly 19 XA0112001 LCD module 20 X56286001 Lead wire assembly 21 XA0113001 Scanner B5N 1771 22 085300815 Screw 23 138433001 Screw Accessories Packing 24 XA0051001 Original sheet 25 X61051001 Carton X61052001 Carton BabyLock 26 X60645000 PAD D 27 U...

Page 15: ... 14 www promelectroavtomat ru ...

Page 16: ... 15 122 902 H6120073 www promelectroavtomat ru ...

Reviews: