3-39
Confidential
9.20 Second side CCD unit / Second side CCD flat cable
(1) Release the second side CCD flat cable from the securing fixtures.
(2) Remove the taptite bind B M3x10 (black) screw from the upper base ASSY.
Fig. 3-46
(3) Turn the second side CCD unit so that the cut surface of the left shaft and rib of the
bushing match, and remove it from the upper base ASSY.
Fig. 3-47
Note:
• Be sure to replace the double-sided tape with a new one, after taking off the flat
cable from the double-sided tape.
Note:
• Do not touch the glass surface of second side CCD unit.
Second side
CCD flat cable
Second side CCD unit
Upper base ASSY
Taptite bind B M3x10 (black)
Second side
CCD unit
Rib
Shaft
Upper base ASSY