3-91
Confidential
9.40 MJ PCB ASSY
(1) Release the wiring of the MJ PCB flat cable.
(2) Remove the one screw (TAPTITE CUP S M3x6) and take off the MJ upper frame
from the Main PCB frame.
(3) Remove the one screw (TAPTITE CUP S M3x6) from the MJ PCB ASSY.
(4) Release the Hook and remove the MJ PCB ASSY from the Main PCB frame.
Fig. 3-106
Harness routing:
Refer to
Main PCB ASSY and MJ PCB ASSY"
TAPTITE CUP S M3x6
MJ PCB ASSY
Main PCB frame
Hook
MJ upper frame
2
4
MJ PCB flat cable
<Front>
<Rear>
Insulation film