3-68
Confidential
9.21 First Side CIS Unit
(1) Turn the Document scanner base ASSY upside down.
(2) Remove the five screws (TAPTITE CUP B M3x10) from the Document scanner
base ASSY.
Assembling Note:
When tightening the five screws (TAPTITE CUP B M3x10), tighten
them in the order shown in the figure.
Fig. 3-70
TAPTITE CUP
TAPTITE CUP B M3x10
Document scanner base ASSY
2
1
3
4
5
B M3x10