![Brother MFC-J3530DW Service Manual Download Page 66](http://html.mh-extra.com/html/brother/mfc-j3530dw/mfc-j3530dw_service-manual_54263066.webp)
Confidential
2-26
■
Error Code 1300
Defective during duplex-printing
- Registration sensor detects paper feed condition at out of specified timing during
switchback.
< User Check >
- Check that recording paper is not loaded in the MP tray and/or manual feed slot.
- Check whether the recording paper being used is within the specification.
- Check that Output paper tray is set correctly (not inserted halfway).
■
Error Code 1500
Paper jam during duplex ejecting
- Recording paper is not able to be ejected since it is longer than 840 mm when ejecting
the paper. (The registration sensor stays in the paper feeding condition during
ejecting.)
< User Check >
- Remove the jammed paper.
- Check whether the recording paper being used is within the specification.
Step
Cause
Solution
1
Registration actuator caught
on the surrounding parts
Set the registration actuator into place.
2
Switchback actuator caught on
the surrounding parts
Set the switchback frame ASSY into place.
3
Registration sensor defective
Replace the registration sensor PCB.
4
Main PCB defective
Replace the main PCB.
Step
Cause
Solution
1
Foreign materials in the
recording paper path
Remove foreign materials.
2
Registration actuator caught
on the surrounding parts
Set the registration actuator into place.
3
Main PCB defective
Replace the main PCB.