2-32
Confidential
Error code 0E00
Communication between the panel PCB and the main PCB cannot be established at
machine startup.
Error code 0F00
The back cover sensor detected that the cover was open in duplex printing mode.
Error codes 1000 to 1D00
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
An unidentified error occurred.
---
Step
Cause
Remedy
1
Connection failure of the panel
PCB harness
Reconnect the panel PCB harness.
2
Panel PCB failure
Replace the panel PCB ASSY.
3
Touch panel PCB failure
Replace the touch panel PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
Duplex Disabled
Close the Back Cover of the machine and put the Duplex Tray back in.
<User Check>
• Close the back cover.
• Set the duplex tray.
Step
Cause
Remedy
1
Connection failure of the back
cover sensor harness
Check the connection of the back cover sensor
harness, and reconnect it if necessary.
2
Back cover sensor attachment
failure
Reattach the back cover sensor.
3
Broken rib (on the right inside
the back cover) where the back
cover switch is pressed
Replace the back cover.
4
Damaged duplex tray
Replace the duplex tray.
5
Back cover sensor failure
Replace the back cover switch harness ASSY.
6
Main PCB failure
Replace the main PCB ASSY.
---
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for MFC-8510DN
Page 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Page 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 300: ...5 5 Confidential Fig 5 1 ...
Page 325: ...5 30 Confidential Fig 5 14 ...
Page 327: ...5 32 Confidential Fig 5 15 ...
Page 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Page 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...