LK3-B448E MARKII/BA-16
10. Adjustment
54
S E L E C T
PROGRAM NO.
R E S E T
COUNTER
X-SCALE
Y-SCALE
SPEED
P
T E S T
BOBBIN.WIND
P4
P3
P1
P2
POWER
r
e
t
200V
220V
230V
100V
380V
400V
415V
Display
[090 - 110]
[100 - 120]
[105 - 125]
[100 - 120]
Notes
“100” is displayed when the input voltage is 200 V.
“110” is displayed when the input voltage is
100V (for 100-V spece.), 380V (for 380-V spece.),
400V (for 400-V spece.)or 415V (for 415-V spece.).
Specifications
w
q
10-19. Checking the input voltage
1. Turn on the power switch.
2. Press the SELECT switch
q
until the Y-SCALE indicator
w
illuminates.
3. While pressing the TEST switch
e
, press the RESET switch
r
.
4. If the input voltage is normal, the input voltage conditions will be shown in the display window
t
as indicated in the
table above.
5. Press the TEST switch
e
again to return the display to the normal condition.