2-26
Confidential
4.6
Troubleshooting for Network Problems
4.6.1 Cannot scan via network connection
4.6.2 Cannot connect to access point
<User Check>
- Check the relevant section in the Network Setting Guide.
- Check the network connection.
- Reset the network. (Refer to the User's Guide.)
- Check the LAN cable.
Step
Cause
Remedy
1
Connection failure of the wireless
LAN PCB connector
Reconnect the wireless LAN PCB ASSY
connector.
2
Wireless LAN PCB failure
Replace the wireless LAN PCB ASSY.
3
Deformed LAN terminal pin
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Check the wireless LAN settings.
- Check the access point settings.
- Change the machine installation location.
- Set the access point manually.
Step
Cause
Remedy
1
Invalid wireless LAN setting
Enable the WSW54 selector 4 setting.