3-42
Confidential
9.13 High voltage power supply PCB ASSY
(1) Remove the Flat cable from the Guides of the Main frame R ASSY, and disconnect the
connector from the High voltage power supply PCB ASSY.
(2) Remove the Taptite bind B M4x12 screw.
(3) Release the Hooks to remove the High voltage power supply PCB ASSY.
Fig. 3-40
Assembling Note:
• Assemble the Front cover sensor lever after assembling the High voltage power supply
PCB ASSY.
Guide
Guide
Main frame R ASSY
Front cover sensor lever
Flat cable
Flat cable
High voltage power
supply PCB ASSY
Hook
Hooks
Taptite bind B M4x12